Influence of Wire Misalignment in Current Injection Probe on the Bulk Current Injection (BCI) Test

In this paper, the wire misalignment inside the current injection probe during BCI testing is analyzed. It is critically examined whether a wire misalignment has a significant impact on the total measurement uncertainty and the reproducibility of the BCI test. For this analysis, a special fixation for a cable wire inside the current injection probe was developed to evaluate different positions of wire misalignment. After measuring the 13 different misalignment positions of the wire, the measured data are compared and evaluated. The main purpose of this analysis is then to decide if the misalignment has a significant impact on the BCI test.

Authors

Institutions

Publication Details

Published
2025-06-02
DOI
https://doi.org/10.23919/measurement66999.2025.11078682
Citations
1
Primary Topic
Electrostatic Discharge in Electronics
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Wire Misalignment in Current Injection Probe on the Bulk Current Injection (BCI) Test

Martin Gabrišák, M. Bittera, Michal Dzuriš, Jozef Hallon
1 citations
Electrostatic Discharge in Electronics
0.73
article

Influence of Wire Misalignment in Current Injection Probe on the Bulk Current Injection (BCI) Test

Martin Gabrišák, M. Bittera, Michal Dzuriš, Jozef Hallon
article en
1 citations

Abstract

In this paper, the wire misalignment inside the current injection probe during BCI testing is analyzed. It is critically examined whether a wire misalignment has a significant impact on the total measurement uncertainty and the reproducibility of the BCI test. For this analysis, a special fixation for a cable wire inside the current injection probe was developed to evaluate different positions of wire misalignment. After measuring the 13 different misalignment positions of the wire, the measured data are compared and evaluated. The main purpose of this analysis is then to decide if the misalignment has a significant impact on the BCI test.

Slovak University of Technology in Bratislava (SK)
Openalex Percentile: Top 25%
Electrostatic Discharge in Electronics
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.