Adjustment Algorithm for Multi-Lead QRS Detection

This paper examines a multi-lead adjustment algorithm for multi-lead ECG (electrocardiogram) signals based on single-lead QRS complex detections. The algorithm uses the Pan-Tompkins detector (PTD) and considers statistical parameters like the mode of detections and the average and median lengths of heart-depolarization intervals. The proposed algorithm is evaluated on two EKG databases: Lobachevsky University and Physikalisch-Technische Bundesanstalt diagnostic cardiography databases. The results demonstrate that reducing the acceptable interval for QRS complex timestamp differences during the decision phase increases error rates. Compared to manual QRS timestamps, the adjusted detection shows less than 2% error within chosen intervals considered acceptable for accurate detection.

Authors

Institutions

Publication Details

Published
2025-06-02
DOI
https://doi.org/10.23919/measurement66999.2025.11078714
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adjustment Algorithm for Multi-Lead QRS Detection

Ján Šaliga, Ondrej Kováč, Andrea Kováčová
ECG Monitoring and Analysis
article

Adjustment Algorithm for Multi-Lead QRS Detection

Ján Šaliga, Ondrej Kováč, Andrea Kováčová
article en

Abstract

This paper examines a multi-lead adjustment algorithm for multi-lead ECG (electrocardiogram) signals based on single-lead QRS complex detections. The algorithm uses the Pan-Tompkins detector (PTD) and considers statistical parameters like the mode of detections and the average and median lengths of heart-depolarization intervals. The proposed algorithm is evaluated on two EKG databases: Lobachevsky University and Physikalisch-Technische Bundesanstalt diagnostic cardiography databases. The results demonstrate that reducing the acceptable interval for QRS complex timestamp differences during the decision phase increases error rates. Compared to manual QRS timestamps, the adjusted detection shows less than 2% error within chosen intervals considered acceptable for accurate detection.

Technical University of Košice (SK)
Openalex Percentile: Top 68%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.