On Digital Twin for Multi-Terminal HVDC: Application to Fault Location on the DC Side

In this contribution, we present two important workflows: one dedicated to the design of multiterminal HVDC systems and another focused on the development of digital twin technology. We begin by providing a brief explanation of the design methodology for a multiterminal HVDC system. Next, we detail how the digital twin concept is applied to fault detection and location in the DC grid section of the HVDC system. The fault detection strategy is divided into two phases. In the first phase, the faulty segment is identified by estimating the conductances of various segments. In the second phase, an unscented Kalman filter is employed to determine the exact fault location. The proposed approach is evaluated using four multiterminal test cases, and the results demonstrate that it is promising for HVDC system fault diagnosis.

Authors

Institutions

Publication Details

Published
2025-05-29
DOI
https://doi.org/10.1109/aeithvdc66044.2025.11079519
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On Digital Twin for Multi-Terminal HVDC: Application to Fault Location on the DC Side

Rahul Dutta, Feng He, Sid Ahmed Attia, Sunil Unnikrishan et al.
HVDC Systems and Fault Protection
article

On Digital Twin for Multi-Terminal HVDC: Application to Fault Location on the DC Side

Rahul Dutta, Feng He, Sid Ahmed Attia, Sunil Unnikrishan, Francesca Perino
article en

Abstract

In this contribution, we present two important workflows: one dedicated to the design of multiterminal HVDC systems and another focused on the development of digital twin technology. We begin by providing a brief explanation of the design methodology for a multiterminal HVDC system. Next, we detail how the digital twin concept is applied to fault detection and location in the DC grid section of the HVDC system. The fault detection strategy is divided into two phases. In the first phase, the faulty segment is identified by estimating the conductances of various segments. In the second phase, an unscented Kalman filter is employed to determine the exact fault location. The proposed approach is evaluated using four multiterminal test cases, and the results demonstrate that it is promising for HVDC system fault diagnosis.

Cellworks Research (India) (IN), Tagworks Pharmaceuticals (Netherlands) (NL), MathWorks (United States) (US)
Openalex Percentile: Top 82%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.