A Digital Twin System for the Sitting-to-Standing Motion of the Knee Joint

(1) Background: A severe decline in knee joint function significantly affects the mobility of the elderly, making it a key concern in the field of geriatric health. To alleviate the pressure on the knee joints of the elderly during daily movements such as sitting and standing, effective biomechanical solutions are required. (2) Methods: In this study, a biomechanical framework was established based on mechanical analysis to derive the transfer relationship between the ground reaction force and the knee joint moment. Experiments were designed to collect knee joint data on the elderly during the sit-to-stand process. Meanwhile, magnetic resonance imaging (MRI) images were processed through a medical imaging control system to construct a detailed digital 3D knee joint model. A finite element analysis was used to verify the model to ensure the accuracy of its structure and mechanical properties. An improved radial basis function was used to fit the pressure during the entire sit-to-stand conversion process to reduce the computational workload, with an error of less than 5%. In addition, a small-target human key point recognition network was developed to analyze the image sequences captured by the camera. The knee joint angle and the knee joint pressure distribution during the sit-to-stand conversion process were mapped to a three-dimensional interactive platform to form a digital twin system. (3) Results: The system can effectively capture the biomechanical behavior of the knee joint during movement and shows high accuracy in joint angle tracking and structure simulation. (4) Conclusions: This study provides an accurate and comprehensive method for analyzing the biomechanical characteristics of the knee joint during the movement of the elderly, laying a solid foundation for clinical rehabilitation research and the design of assistive devices in the field of rehabilitation medicine.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-07-18
DOI
https://doi.org/10.3390/electronics14142867
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Digital Twin System for the Sitting-to-Standing Motion of the Knee Joint

Peng Su, Cheng Sun, Tian Liu, Zhijie Chen et al.
Electronics
Prosthetics and Rehabilitation Robotics
article

A Digital Twin System for the Sitting-to-Standing Motion of the Knee Joint

Peng Su, Cheng Sun, Tian Liu, Zhijie Chen, Jian Li, Lei Sun
article en

Abstract

(1) Background: A severe decline in knee joint function significantly affects the mobility of the elderly, making it a key concern in the field of geriatric health. To alleviate the pressure on the knee joints of the elderly during daily movements such as sitting and standing, effective biomechanical solutions are required. (2) Methods: In this study, a biomechanical framework was established based on mechanical analysis to derive the transfer relationship between the ground reaction force and the knee joint moment. Experiments were designed to collect knee joint data on the elderly during the sit-to-stand process. Meanwhile, magnetic resonance imaging (MRI) images were processed through a medical imaging control system to construct a detailed digital 3D knee joint model. A finite element analysis was used to verify the model to ensure the accuracy of its structure and mechanical properties. An improved radial basis function was used to fit the pressure during the entire sit-to-stand conversion process to reduce the computational workload, with an error of less than 5%. In addition, a small-target human key point recognition network was developed to analyze the image sequences captured by the camera. The knee joint angle and the knee joint pressure distribution during the sit-to-stand conversion process were mapped to a three-dimensional interactive platform to form a digital twin system. (3) Results: The system can effectively capture the biomechanical behavior of the knee joint during movement and shows high accuracy in joint angle tracking and structure simulation. (4) Conclusions: This study provides an accurate and comprehensive method for analyzing the biomechanical characteristics of the knee joint during the movement of the elderly, laying a solid foundation for clinical rehabilitation research and the design of assistive devices in the field of rehabilitation medicine.

ElectronicsVol. 14(14)
Beijing University of Posts and Telecommunications (CN), National Research Center for Rehabilitation Technical Aids (CN), Beijing Information Science & Technology University (CN)
Openalex Percentile: Top 81%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.