Uncertainty Quantification of Fluorescence Signals for Cytometry Part <scp>II</scp>: Comparison of Serial and Traditional Flow Cytometers

Flow cytometers are powerful tools for bioanalytical applications, yet new systems that promise better measurements are continuously being introduced as sensors and other technologies advance. One such advancement by NIST was the recently demonstrated a serial microcytometer that enables unique capabilities for uncertainty quantification on a per-object basis. In an effort to benchmark and improve the measurement capabilities of the serial microcytometer, we found limitations to the quantitative comparison of instruments using conventional metrics and methods. To address these shortcomings, we recently developed an improved model that builds upon conventional models to improve comparability (Patrone et al. "Uncertainty Quantification of Fluorescence Signals in Flow Cytometry Part I: An Analytical Perspective Beyond Q and B" submitted in conjunction with this manuscript). In Part I, and continued here, our aim was to develop metrics that enable comparisons based on upper limit of linearity, limit of background, limit of detection, noise-to-signal ratio, and uncertainty decomposition thereof. We found that the NIST serial microcytometer has similar performance capabilities to a conventional analytical flow cytometer. This manuscript continues the development of uncertainty quantification (UQ) for flow cytometry by demonstrating how a serial microcytometer facilitates separation of the instrument-and population-dependent contributions to UQ. Component-level contributions to UQ can also be analyzed. Ultimately, these methods establish robust metrics for instrument performance and introduce per-object uncertainty as a mechanism facilitating better classification and utilization of cytometry data in research and clinical use.

Authors

Institutions

Publication Details

Journal
Cytometry Part A
Published
2025-08-01
DOI
https://doi.org/10.1002/cyto.a.24952
Citations
1
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Quantification of Fluorescence Signals for Cytometry Part II: Comparison of Serial and Traditional Flow Cytometers

Gregory A. Cooksey, Megan A. Catterton, Paul N. Patrone, Matthew DiSalvo
1 citations
Cytometry Part A
Microfluidic and Bio-sensing Technologies
0.67
article

Uncertainty Quantification of Fluorescence Signals for Cytometry Part II: Comparison of Serial and Traditional Flow Cytometers

Gregory A. Cooksey, Megan A. Catterton, Paul N. Patrone, Matthew DiSalvo
article en
1 citations

Abstract

Flow cytometers are powerful tools for bioanalytical applications, yet new systems that promise better measurements are continuously being introduced as sensors and other technologies advance. One such advancement by NIST was the recently demonstrated a serial microcytometer that enables unique capabilities for uncertainty quantification on a per-object basis. In an effort to benchmark and improve the measurement capabilities of the serial microcytometer, we found limitations to the quantitative comparison of instruments using conventional metrics and methods. To address these shortcomings, we recently developed an improved model that builds upon conventional models to improve comparability (Patrone et al. "Uncertainty Quantification of Fluorescence Signals in Flow Cytometry Part I: An Analytical Perspective Beyond Q and B" submitted in conjunction with this manuscript). In Part I, and continued here, our aim was to develop metrics that enable comparisons based on upper limit of linearity, limit of background, limit of detection, noise-to-signal ratio, and uncertainty decomposition thereof. We found that the NIST serial microcytometer has similar performance capabilities to a conventional analytical flow cytometer. This manuscript continues the development of uncertainty quantification (UQ) for flow cytometry by demonstrating how a serial microcytometer facilitates separation of the instrument-and population-dependent contributions to UQ. Component-level contributions to UQ can also be analyzed. Ultimately, these methods establish robust metrics for instrument performance and introduce per-object uncertainty as a mechanism facilitating better classification and utilization of cytometry data in research and clinical use.

Cytometry Part AVol. 107(8)
National Institute of Standards and Technology (US)
National Institute of Standards and Technology
Openalex Percentile: Top 28%
Microfluidic and Bio-sensing Technologies
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.