Impact of self-absorption on dose enhancement induced by metallic nanoparticles

Metallic nanoparticles (NPs) have significant potential to enhance radiotherapy by increasing tumor cell damage while sparing healthy tissues. This radiosensitization effect primarily results from the generation of secondary electrons when radiation interacts with NPs and is quantified by the dose enhancement factor (DEF). However, DEF is influenced by the self-absorption effect, which depends on NP size, composition, and the incident radiation energy. In this study, we used the Monte Carlo simulation code PENELOPE (version 2014) to quantify self-absorption effects in various NP configurations and radiation beams. Simulations were conducted by varying NP material (gold, silver, platinum, and bismuth), size, and concentration, while exposing them to X-rays at 100 kVp and 6 MV, as well as gamma rays from<sup>192</sup>Ir and<sup>60</sup>Co sources. The resulting secondary electron spectra were analyzed to determine key parameters, including average energy, range, and DEF. Results indicate that for all analyzed beams and materials, both the energy and average range of secondary electrons increase with NP size. DEF is maximized for low-energy beams and for materials with high atomic numbers and concentrations, as well as for the smallest NPs due to self-absorption. At 100 kVp and 1% NP concentration of gold for example, DEF decreased by 9.5% when NP size increased from 2 nm to 100 nm, whereas for higher-energy beams (6 MV and<sup>60</sup>Co), this reduction was below 0.1% across all materials and concentrations. These findings reinforce the potential of NPs in radiotherapy and highlight the impact of self-absorption on NP dosimetry, affecting mean energy, range, and DEF. Notably, self-absorption is most pronounced for lowenergy beams - the same conditions where DEF is maximized.&#xD.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-08-08
DOI
https://doi.org/10.1088/1361-6560/adf9b4
Citations
1
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
1.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of self-absorption on dose enhancement induced by metallic nanoparticles

S. Alba, Gabriela Corati Touguinha, Mirko Salomón Alva-Sánchez, Henrique Trombini et al.
1 citations
Physics in Medicine and Biology
Radiation Therapy and Dosimetry
1.52
article

Impact of self-absorption on dose enhancement induced by metallic nanoparticles

S. Alba, Gabriela Corati Touguinha, Mirko Salomón Alva-Sánchez, Henrique Trombini, Leonardo Pessoa da Silva, Thatiane Alves Pianoschi
article en
1 citations

Abstract

Metallic nanoparticles (NPs) have significant potential to enhance radiotherapy by increasing tumor cell damage while sparing healthy tissues. This radiosensitization effect primarily results from the generation of secondary electrons when radiation interacts with NPs and is quantified by the dose enhancement factor (DEF). However, DEF is influenced by the self-absorption effect, which depends on NP size, composition, and the incident radiation energy. In this study, we used the Monte Carlo simulation code PENELOPE (version 2014) to quantify self-absorption effects in various NP configurations and radiation beams. Simulations were conducted by varying NP material (gold, silver, platinum, and bismuth), size, and concentration, while exposing them to X-rays at 100 kVp and 6 MV, as well as gamma rays from<sup>192</sup>Ir and<sup>60</sup>Co sources. The resulting secondary electron spectra were analyzed to determine key parameters, including average energy, range, and DEF. Results indicate that for all analyzed beams and materials, both the energy and average range of secondary electrons increase with NP size. DEF is maximized for low-energy beams and for materials with high atomic numbers and concentrations, as well as for the smallest NPs due to self-absorption. At 100 kVp and 1% NP concentration of gold for example, DEF decreased by 9.5% when NP size increased from 2 nm to 100 nm, whereas for higher-energy beams (6 MV and<sup>60</sup>Co), this reduction was below 0.1% across all materials and concentrations. These findings reinforce the potential of NPs in radiotherapy and highlight the impact of self-absorption on NP dosimetry, affecting mean energy, range, and DEF. Notably, self-absorption is most pronounced for lowenergy beams - the same conditions where DEF is maximized.&#xD.

Physics in Medicine and BiologyVol. 70(17)
Universidade Federal do Rio Grande do Sul (BR), Universidade Federal de Ciências da Saúde de Porto Alegre (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul
Affordable and clean energy
Openalex Percentile: Top 15%
Radiation Therapy and Dosimetry
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.