Point-of-care testing of nitrite in oral medicine - Application and validation of an enzymatic biosensor in human saliva
Periodontal disease (PD) is a chronic inflammatory condition triggered by bacterial biofilms and progresses through two main stages: gingivitis and periodontitis. The existing diagnostic methods remain time-consuming and require clinical expertise. Salivary nitrite, a stable end-product of nitric oxide produced during inflammation, has emerged as a promising biomarker for PD. However, its reliable quantification in saliva typically relies on laboratory-based assays that are unsuited to clinical workflows. This study aimed to test and validate a new nitrite point-of-care test (POCT) for oral medicine. Building on previous research, we developed a biosensing platform based on screen-printed carbon electrodes modified with a selective enzyme, the cytochrome c nitrite reductase. To adapt bioelectrodes for salivary analysis, they were further modified with a poly(vinyl) alcohol coating and a biochemical oxygen scavenger system (ascorbate oxidase and ascorbate). The nitrite biosensor achieved a suitable linear range of 5–300 μM, with a sensitivity of 0.015 μM −1 , validated against the gold-standard Griess method. Unlike the Griess reaction, the biosensor was unaffected by sample turbidity, rendering centrifugation unnecessary. Additionally, we observed that sample freezing altered nitrite concentrations, increasing levels in non-centrifuged samples, while decreasing them in previously clarified samples. These findings highlight the need for real-time analysis and call into question the reliability of previously published data that overlooked these variables. Therefore, our results demonstrate the potential of the nitrite biosensor as a novel salivary POCT and emphasize the critical need for standardized sample-handling protocols. • A biosensor-based point-of-care test was developed for rapid salivary nitrite analysis. • Biosensor performance was enhanced by a mono-enzymatic oxygen scavenger system and polymeric coating. • Direct saliva analysis is enabled without centrifugation, as the biosensor is unaffected by sample turbidity. • Freeze-storage of saliva samples impacts nitrite concentration, highlighting the need for real-time analysis.
Authors
- Ricardo Alves (ORCID: https://orcid.org/0000-0001-7184-5965)
- M. Gabriela Almeida (ORCID: https://orcid.org/0000-0002-4508-7379)
- S Gáspár (ORCID: https://orcid.org/0000-0003-0778-6475)
- Luís Proença (ORCID: https://orcid.org/0000-0002-8482-5936)
Institutions
- Escola Superior de Saúde Egas Moniz (PT)
- Universidade Nova de Lisboa (PT)
Publication Details
- Journal
- Sensing and Bio-Sensing Research
- Published
- 2025-08-01
- DOI
- https://doi.org/10.1016/j.sbsr.2025.100860
- Citations
- 1
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.73
Funders
- Applied Molecular Biosciences Unit
- Rede de Química e Tecnologia
- Laboratório Associado para a Química Verde
- Fundação para a Ciência e a Tecnologia