Evaluation of end-to-end 3D absorbed dose distribution in 90Y-SIRT and SBRT combination therapy using MAGIC-f polymer gel dosimeter

This is the first study demonstrating the feasibility of using MAGIC-f gel dosimetry to directly measure 3D dose distributions from combined <sup>90</sup>Y-SIRT and SBRT. Compared to PET/CT-based dosimetry, the gel method offers superior spatial resolution and enables objective physical verification of complex dose distributions. This technique has strong potential for quality assurance in theranostic protocols, particularly for beta emitters and, potentially, alpha-emitting radiotracers in future applications.

Authors

Institutions

Publication Details

Journal
European Journal of Nuclear Medicine and Molecular Imaging
Published
2025-08-08
DOI
https://doi.org/10.1007/s00259-025-07461-2
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of end-to-end 3D absorbed dose distribution in 90Y-SIRT and SBRT combination therapy using MAGIC-f polymer gel dosimeter

Yazdan Salimi, Habib Zaidi, Nikolaos Koutsouvelis, Zahra Mansouri
1 citations
European Journal of Nuclear Medicine and Molecular Imaging
Advanced Radiotherapy Techniques
1.88
article

Evaluation of end-to-end 3D absorbed dose distribution in 90Y-SIRT and SBRT combination therapy using MAGIC-f polymer gel dosimeter

Yazdan Salimi, Habib Zaidi, Nikolaos Koutsouvelis, Zahra Mansouri
article en
1 citations

Abstract

This is the first study demonstrating the feasibility of using MAGIC-f gel dosimetry to directly measure 3D dose distributions from combined <sup>90</sup>Y-SIRT and SBRT. Compared to PET/CT-based dosimetry, the gel method offers superior spatial resolution and enables objective physical verification of complex dose distributions. This technique has strong potential for quality assurance in theranostic protocols, particularly for beta emitters and, potentially, alpha-emitting radiotracers in future applications.

European Journal of Nuclear Medicine and Molecular ImagingVol. 53(2)
Obuda University (HU), University Medical Center Groningen (NL), University of Southern Denmark (DK), University Hospital of Geneva (CH)
National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Université de Genève, Centre d'Imagerie BioMédicale
Good health and well-being
Openalex Percentile: Top 14%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.