Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers

3-Nitro-l-tyrosine (NO<sub>2</sub>Tyr) serves as a critical biomarker of oxidative stress, closely linked to the pathogenesis of neurodegenerative and inflammatory disorders. This study presents a highly sensitive and selective nonenzymatic electrochemical sensor that uses polymer nanozyme properties for the detection of NO<sub>2</sub>Tyr in human saliva. The sensor design integrates molecularly imprinted poly(3-aminophenol) (MIP) films, electropolymerized directly onto graphitic electrodes (GPE) via cyclic voltammetry (CV), with NO<sub>2</sub>Tyr acting as the molecular template. By mimicking enzyme-substrate recognition, the MIP/GPE sensor exhibits superior electrochemical performance without relying on biological enzymes. Surface analysis confirms uniform MIP film formation, while electrochemical characterization reveals a significant reduction in charge transfer resistance and enhanced electroactive surface area, facilitating rapid electron transfer critical for sensitive NO<sub>2</sub>Tyr detection. Sensor measurements reveal a linear detection range of 0-1000 nM, a low limit of detection (LOD) of 0.21 nM, and a sensitivity of 0.94 μA cm<sup>-2</sup> nM<sup>-1</sup> toward NO<sub>2</sub>Tyr. The sensor maintains high selectivity against common salivary interferents, including structurally similar l-tyrosine (Tyr), and achieves an overall 95.9% recovery rate in different human saliva samples. This MIP-based sensing platform introduces an effective enzyme-mimetic strategy for selective NO<sub>2</sub>Tyr recognition, offering a robust, disposable, and cost-efficient tool for point-of-care (PoC) monitoring of oxidative stress biomarkers. Its operational simplicity, stability, and compatibility with complex biological fluids position it as a promising candidate for early stage screening and management of oxidative stress-associated neurodegenerative diseases.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2025-08-08
DOI
https://doi.org/10.1021/acsabm.5c01212
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers

Adnan Mujahid, Adeel Afzal, Kanza Maryam
2 citations
ACS Applied Bio Materials
Electrochemical sensors and biosensors
1.46
article

Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers

Adnan Mujahid, Adeel Afzal, Kanza Maryam
article en
2 citations

Abstract

3-Nitro-l-tyrosine (NO<sub>2</sub>Tyr) serves as a critical biomarker of oxidative stress, closely linked to the pathogenesis of neurodegenerative and inflammatory disorders. This study presents a highly sensitive and selective nonenzymatic electrochemical sensor that uses polymer nanozyme properties for the detection of NO<sub>2</sub>Tyr in human saliva. The sensor design integrates molecularly imprinted poly(3-aminophenol) (MIP) films, electropolymerized directly onto graphitic electrodes (GPE) via cyclic voltammetry (CV), with NO<sub>2</sub>Tyr acting as the molecular template. By mimicking enzyme-substrate recognition, the MIP/GPE sensor exhibits superior electrochemical performance without relying on biological enzymes. Surface analysis confirms uniform MIP film formation, while electrochemical characterization reveals a significant reduction in charge transfer resistance and enhanced electroactive surface area, facilitating rapid electron transfer critical for sensitive NO<sub>2</sub>Tyr detection. Sensor measurements reveal a linear detection range of 0-1000 nM, a low limit of detection (LOD) of 0.21 nM, and a sensitivity of 0.94 μA cm<sup>-2</sup> nM<sup>-1</sup> toward NO<sub>2</sub>Tyr. The sensor maintains high selectivity against common salivary interferents, including structurally similar l-tyrosine (Tyr), and achieves an overall 95.9% recovery rate in different human saliva samples. This MIP-based sensing platform introduces an effective enzyme-mimetic strategy for selective NO<sub>2</sub>Tyr recognition, offering a robust, disposable, and cost-efficient tool for point-of-care (PoC) monitoring of oxidative stress biomarkers. Its operational simplicity, stability, and compatibility with complex biological fluids position it as a promising candidate for early stage screening and management of oxidative stress-associated neurodegenerative diseases.

ACS Applied Bio MaterialsVol. 8(9)
University of the Punjab (PK)
Royal Society of Chemistry
Openalex Percentile: Top 16%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.