Polymer Nanozymes: Electropolymerized Enzyme Mimics for the Detection of Oxidative Stress Biomarkers
3-Nitro-l-tyrosine (NO<sub>2</sub>Tyr) serves as a critical biomarker of oxidative stress, closely linked to the pathogenesis of neurodegenerative and inflammatory disorders. This study presents a highly sensitive and selective nonenzymatic electrochemical sensor that uses polymer nanozyme properties for the detection of NO<sub>2</sub>Tyr in human saliva. The sensor design integrates molecularly imprinted poly(3-aminophenol) (MIP) films, electropolymerized directly onto graphitic electrodes (GPE) via cyclic voltammetry (CV), with NO<sub>2</sub>Tyr acting as the molecular template. By mimicking enzyme-substrate recognition, the MIP/GPE sensor exhibits superior electrochemical performance without relying on biological enzymes. Surface analysis confirms uniform MIP film formation, while electrochemical characterization reveals a significant reduction in charge transfer resistance and enhanced electroactive surface area, facilitating rapid electron transfer critical for sensitive NO<sub>2</sub>Tyr detection. Sensor measurements reveal a linear detection range of 0-1000 nM, a low limit of detection (LOD) of 0.21 nM, and a sensitivity of 0.94 μA cm<sup>-2</sup> nM<sup>-1</sup> toward NO<sub>2</sub>Tyr. The sensor maintains high selectivity against common salivary interferents, including structurally similar l-tyrosine (Tyr), and achieves an overall 95.9% recovery rate in different human saliva samples. This MIP-based sensing platform introduces an effective enzyme-mimetic strategy for selective NO<sub>2</sub>Tyr recognition, offering a robust, disposable, and cost-efficient tool for point-of-care (PoC) monitoring of oxidative stress biomarkers. Its operational simplicity, stability, and compatibility with complex biological fluids position it as a promising candidate for early stage screening and management of oxidative stress-associated neurodegenerative diseases.
Authors
- Adnan Mujahid (ORCID: https://orcid.org/0000-0002-0903-7788)
- Adeel Afzal (ORCID: https://orcid.org/0000-0002-6528-7300)
- Kanza Maryam (ORCID: https://orcid.org/0000-0003-1085-1346)
Institutions
- University of the Punjab (PK)
Publication Details
- Journal
- ACS Applied Bio Materials
- Published
- 2025-08-08
- DOI
- https://doi.org/10.1021/acsabm.5c01212
- Citations
- 2
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 1.46
Funders
- Royal Society of Chemistry