Resilience In Compression: Comparative Evaluation Of Elastic Recovery In Two Commercially Available Addition Silicone Impression Materials

This in vitro study evaluates and compares the elastic recovery under compressive strain of two commercially available addition silicone impression materials—Dentsply Aquasil and Ad Sil Acura. Standardized cylindrical specimens (20 mm × 12.5 mm) were prepared per ISO 4823:2007 and subjected to 30% compressive strain using a Universal Testing Machine. Recovery height was measured after 2 minutes, and recovery percentage was calculated. Dentsply Aquasil showed higher elastic recovery (98.5%) than Ad Sil Acura (96.9%), with statistical significance (p < 0.05). Results suggest Dentsply Aquasil provides better dimensional stability for clinical use.

Authors

Publication Details

Journal
African Journal of Biomedical Research
Published
2025-01-01
DOI
https://doi.org/10.53555/ajbr.v28i3s.8213
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilience In Compression: Comparative Evaluation Of Elastic Recovery In Two Commercially Available Addition Silicone Impression Materials

Prashant Patil, Dr.Maitreyee Pathak, Dr.Premraj Jadhav, Pradeep Taide et al.
African Journal of Biomedical Research
Orthopaedic implants and arthroplasty
article

Resilience In Compression: Comparative Evaluation Of Elastic Recovery In Two Commercially Available Addition Silicone Impression Materials

Prashant Patil, Dr.Maitreyee Pathak, Dr.Premraj Jadhav, Pradeep Taide, Dr.Joel Koshy, Dr.Shreyas Nazirkar
article en

Abstract

This in vitro study evaluates and compares the elastic recovery under compressive strain of two commercially available addition silicone impression materials—Dentsply Aquasil and Ad Sil Acura. Standardized cylindrical specimens (20 mm × 12.5 mm) were prepared per ISO 4823:2007 and subjected to 30% compressive strain using a Universal Testing Machine. Recovery height was measured after 2 minutes, and recovery percentage was calculated. Dentsply Aquasil showed higher elastic recovery (98.5%) than Ad Sil Acura (96.9%), with statistical significance (p < 0.05). Results suggest Dentsply Aquasil provides better dimensional stability for clinical use.

African Journal of Biomedical Research
Openalex Percentile: Top 67%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.