CIRCUIT ANALYSIS OF PARALLEL RESISTANCE ARRAY SHOCK WAVE POSITION SENSOR

Due to the extremely short duration of shock waves acting on materials, to accurately analyze the physical properties of materials under shock action, sensors with very high measurement accuracy are required. This paper designs a parallel resistance array shock wave position sensor, which uses an electric probe connected to several columns of parallel resistances to measure the moment when the shock wave reaches the point under test, thereby determining the evolution law of the shock wave front in the material. In the paper, a model consistent with the actual circuit is built using Simulink in Matlab to analyze the impact of several component parameters on the relaxation time of the voltage drop edge of the sensor output. The results show that the relaxation time of the voltage drop edge of the parallel sensor is all below 11ns, and less than that of the equivalent component parameter series sensor (35ns), effectively improving the measurement accuracy. The results in the paper provide a reliable theoretical basis for the design of shock wave position sensors and the selection of component parameters in experiments.

Authors

Publication Details

Journal
Wuli yu gongcheng.
Published
2025-04-01
DOI
https://doi.org/10.26599/phys.2025.9320238
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

CIRCUIT ANALYSIS OF PARALLEL RESISTANCE ARRAY SHOCK WAVE POSITION SENSOR

Sixu WANG, Xiaomin Ma, Cheng Zeng, Xuan Wu et al.
Wuli yu gongcheng.
Advanced MEMS and NEMS Technologies
article

CIRCUIT ANALYSIS OF PARALLEL RESISTANCE ARRAY SHOCK WAVE POSITION SENSOR

Sixu WANG, Xiaomin Ma, Cheng Zeng, Xuan Wu, Feng Yuan
article en

Abstract

Due to the extremely short duration of shock waves acting on materials, to accurately analyze the physical properties of materials under shock action, sensors with very high measurement accuracy are required. This paper designs a parallel resistance array shock wave position sensor, which uses an electric probe connected to several columns of parallel resistances to measure the moment when the shock wave reaches the point under test, thereby determining the evolution law of the shock wave front in the material. In the paper, a model consistent with the actual circuit is built using Simulink in Matlab to analyze the impact of several component parameters on the relaxation time of the voltage drop edge of the sensor output. The results show that the relaxation time of the voltage drop edge of the parallel sensor is all below 11ns, and less than that of the equivalent component parameter series sensor (35ns), effectively improving the measurement accuracy. The results in the paper provide a reliable theoretical basis for the design of shock wave position sensors and the selection of component parameters in experiments.

Wuli yu gongcheng.Vol. 35(2)
Affordable and clean energy
Openalex Percentile: Top 82%
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CIRCUIT ANALYSIS OF PARALLEL RESISTANCE ARRAY SHOCK WAVE POSITION SENSOR — Sixu WANG, Xiaomin Ma, et al. · Wuli yu gongcheng. (2025) | TGRS Research Map | TGRS