From Nail to Fail: Complications Encountered with Clavicle Nailing – A Series of 3 Cases
This case series highlights the potential complications associated with clavicle nailing, emphasizing the need for proper technique and research on implant design. Although clavicle nailing has the advantages of being minimally invasive with lesser soft tissue stripping, clavicle plating remains the gold standard as it provides more rigid fixation and promotes early rehabilitation and recovery. If clavicle nailing is being done, one must be aware of potential complications such as non-union, implant migration, hardware failure, and infections. Early referral and timely intervention are crucial for favorable outcomes.
Authors
- Mohamed Sameer
- J. K. Giriraj
- S Srijay Sashaank
- S Udayan
Institutions
- Sri Ramachandra Institute of Higher Education and Research (IN)
Publication Details
- Journal
- Journal of Orthopaedic Case Reports
- Published
- 2025-01-01
- DOI
- https://doi.org/10.13107/jocr.2025.v15.i08.5958
- Primary Topic
- Shoulder and Clavicle Injuries
- Type
- article
- Field-Weighted Citation Impact
- 0.00