Production of Recombinant Phage Antibodies Specific to Gentamicin and Their Use in Dot Immunoassay

The potential of using phage display technology to obtain antigentamicin antibodies has been demonstrated. For the first time antigentamicin recombinant antibodies were obtained using a sheep phage library (Griffin.1, United Kingdom). The interaction between the obtained phage antibodies with gentamicin was monitored using a circular dichroism spectrometer. It was shown that the interaction of antigentamicin phage antibodies with the corresponding antibiotic is characterized by the presence of a characteristic exciton doublet: a positive peak at ~233 nm and a more intense negative peak with a maximum at ~240 nm. The possibility of gentamicin indication using a test system based on the dot immunoassay method and antigentamicin recombinant antibodies in aqueous solutions has been demonstrated for the first time; the lower limit of antibiotic detection is 0.5 μg/mL. Using the dot immunoassay method, it was found that antigentamicin phage antibodies did not exhibit activity towards ampicillin and tetracycline but showed activity towards kanamycin (lower limit of detection, 1 μg/mL). The results are promising for further development of methods for gentamicin detection using recombinant phage antibodies.

Authors

Institutions

Publication Details

Journal
Applied Biochemistry and Microbiology
Published
2025-08-01
DOI
https://doi.org/10.1134/s0003683825600253
Primary Topic
Monoclonal and Polyclonal Antibodies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Production of Recombinant Phage Antibodies Specific to Gentamicin and Their Use in Dot Immunoassay

Д. С. Чумаков, Vyacheslav S. Grinev, О. А. Караваева, О. I. Guliy
Applied Biochemistry and Microbiology
Monoclonal and Polyclonal Antibodies Research
article

Production of Recombinant Phage Antibodies Specific to Gentamicin and Their Use in Dot Immunoassay

Д. С. Чумаков, Vyacheslav S. Grinev, О. А. Караваева, О. I. Guliy
article en

Abstract

The potential of using phage display technology to obtain antigentamicin antibodies has been demonstrated. For the first time antigentamicin recombinant antibodies were obtained using a sheep phage library (Griffin.1, United Kingdom). The interaction between the obtained phage antibodies with gentamicin was monitored using a circular dichroism spectrometer. It was shown that the interaction of antigentamicin phage antibodies with the corresponding antibiotic is characterized by the presence of a characteristic exciton doublet: a positive peak at ~233 nm and a more intense negative peak with a maximum at ~240 nm. The possibility of gentamicin indication using a test system based on the dot immunoassay method and antigentamicin recombinant antibodies in aqueous solutions has been demonstrated for the first time; the lower limit of antibiotic detection is 0.5 μg/mL. Using the dot immunoassay method, it was found that antigentamicin phage antibodies did not exhibit activity towards ampicillin and tetracycline but showed activity towards kanamycin (lower limit of detection, 1 μg/mL). The results are promising for further development of methods for gentamicin detection using recombinant phage antibodies.

Applied Biochemistry and MicrobiologyVol. 61(4)
Saratov State University (RU), Institute of Biochemistry and Physiology of Plants and Microorganisms (RU)
Zero hunger
Openalex Percentile: Top 71%
Monoclonal and Polyclonal Antibodies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.