Micro-structure characteristics and the fire-extinguishing performance of aqueous film-forming foam mixed with short-chain fluorocarbon surfactant

The environmental persistence of perfluorinated compounds derived from long-chain fluorocarbon surfactants in aqueous film-forming foam (AFFF) necessitates the development of eco-friendly alternatives. The short-chain fluorocarbon surfactants (C < 8) are promising substitutes due to their reduced bioaccumulation potential while maintaining surface activity. An amphoteric short-chain fluorocarbon surfactant, namely Capstone® FS-50 (FS-50), was used in this study. The micro-structure characteristics and fire-extinguishing performance of the AFFF mixed with FS-50 was evaluated systematically. By comparing the foaming ability, bubble distribution, liquid drainage rate and bubble size, the test results indicate that the addition FS-50 can effectively delay the burst rate of the foam, and the foaming ability can also improve slightly. This feature can effectively improve fire-extinguishing performance, the fire extinguishing time has been reduced by 60%. On this basis, the relationship between the ambient velocity and fire-extinguishing time was explored. The fire-extinguishing time and the temperature reduction rate are also no longer change when the ambient velocity exceeds 2.5 m/s. Finally, a new prediction model of fire-extinguishing efficiency based on the fire-extinguishing time and temperature change rate was proposed to evaluate the fire-extinguishing performance of foam with different components. These findings provide critical insights into the effect of short-chain fluorocarbon surfactant in AFFF and establish a framework for evaluating AFFF performance in real fire scenarios, advancing the development of environmentally sustainable fire-fighting agents.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0279593
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Micro-structure characteristics and the fire-extinguishing performance of aqueous film-forming foam mixed with short-chain fluorocarbon surfactant

Rong Sun, Juntao Yang, Peng Xiao, Wei Wang et al.
Physics of Fluids
Per- and polyfluoroalkyl substances research
article

Micro-structure characteristics and the fire-extinguishing performance of aqueous film-forming foam mixed with short-chain fluorocarbon surfactant

Rong Sun, Juntao Yang, Peng Xiao, Wei Wang, Zhengyang Wang, Hao Wang
article en

Abstract

The environmental persistence of perfluorinated compounds derived from long-chain fluorocarbon surfactants in aqueous film-forming foam (AFFF) necessitates the development of eco-friendly alternatives. The short-chain fluorocarbon surfactants (C < 8) are promising substitutes due to their reduced bioaccumulation potential while maintaining surface activity. An amphoteric short-chain fluorocarbon surfactant, namely Capstone® FS-50 (FS-50), was used in this study. The micro-structure characteristics and fire-extinguishing performance of the AFFF mixed with FS-50 was evaluated systematically. By comparing the foaming ability, bubble distribution, liquid drainage rate and bubble size, the test results indicate that the addition FS-50 can effectively delay the burst rate of the foam, and the foaming ability can also improve slightly. This feature can effectively improve fire-extinguishing performance, the fire extinguishing time has been reduced by 60%. On this basis, the relationship between the ambient velocity and fire-extinguishing time was explored. The fire-extinguishing time and the temperature reduction rate are also no longer change when the ambient velocity exceeds 2.5 m/s. Finally, a new prediction model of fire-extinguishing efficiency based on the fire-extinguishing time and temperature change rate was proposed to evaluate the fire-extinguishing performance of foam with different components. These findings provide critical insights into the effect of short-chain fluorocarbon surfactant in AFFF and establish a framework for evaluating AFFF performance in real fire scenarios, advancing the development of environmentally sustainable fire-fighting agents.

Physics of FluidsVol. 37(8)
New York City Fire Department (US), State Grid Corporation of China (China) (CN), Shanghai Fire Research Institute (CN), Shanghai Electric (China) (CN)
Natural Science Foundation of Shanghai, National Key Research and Development Program of China
Openalex Percentile: Top 83%
Per- and polyfluoroalkyl substances research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.