Acoustic holography for characterisation of sub-megahertz frequency medical ultrasound sources

Ultrasonic sources operating in the 0.2-1 MHz range are employed in transcranial ultrasound applications to minimise skull-induced aberrations and absorption. Characterizing these acoustic sources is crucial to modelling in situ fields in the brain. However, measurement best practice for sub-MHz sources is not well-established, and guidelines developed for MHz medical ultrasound sources may not apply when similar source apertures are operated at lower frequencies. Here, errors in acoustic fields projected from measured holograms are investigated experimentally using three transducers operating frequencies between 270 and 750 kHz. Errors in reconstruction of the focal regions compared to measurement were less than 2% for measurement planes approximately 1.3 times the -20 dB beam diameter, and root mean square errors were less than 2% for measurement planes more than two times the -20 dB diameter, acquired between the source and focus. Larger measurement planes are required to reduce errors for these lower frequencies compared to fields generated by sources operating at 1 MHz and above.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-08-01
DOI
https://doi.org/10.1121/10.0038755
Citations
2
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acoustic holography for characterisation of sub-megahertz frequency medical ultrasound sources

Eleanor Martin, Rui Xu, W. Zheng
2 citations
The Journal of the Acoustical Society of America
Ultrasound Imaging and Elastography
2.72
article

Acoustic holography for characterisation of sub-megahertz frequency medical ultrasound sources

Eleanor Martin, Rui Xu, W. Zheng
article en
2 citations

Abstract

Ultrasonic sources operating in the 0.2-1 MHz range are employed in transcranial ultrasound applications to minimise skull-induced aberrations and absorption. Characterizing these acoustic sources is crucial to modelling in situ fields in the brain. However, measurement best practice for sub-MHz sources is not well-established, and guidelines developed for MHz medical ultrasound sources may not apply when similar source apertures are operated at lower frequencies. Here, errors in acoustic fields projected from measured holograms are investigated experimentally using three transducers operating frequencies between 270 and 750 kHz. Errors in reconstruction of the focal regions compared to measurement were less than 2% for measurement planes approximately 1.3 times the -20 dB beam diameter, and root mean square errors were less than 2% for measurement planes more than two times the -20 dB diameter, acquired between the source and focus. Larger measurement planes are required to reduce errors for these lower frequencies compared to fields generated by sources operating at 1 MHz and above.

The Journal of the Acoustical Society of AmericaVol. 158(2)
University College London (GB)
Wellcome / EPSRC Centre for Interventional and Surgical Sciences, Medical Research Council
Openalex Percentile: Top 9%
Ultrasound Imaging and Elastography
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Acoustic holography for characterisation of sub-megahertz frequency medical ultrasound sources — Eleanor Martin, Rui Xu, et al. · The Journal of the Acoustical Society of America (2025) | TGRS Research Map | TGRS