An analysis of seismic behavior of brick shear wall in cold-formed steel frame

The light steel frame system is a new construction technology system and is more economical than other construction methods due to its lightness, ease of installation, high execution speed, and ease of repair. In this article, for the first time, the effect of stud spacing and execution method on the seismic behavior of brick shear walls in a cold-formed steel frame (CFSF) was investigated. For this purpose, 6 shear walls, A1: shear wall was made of steel frame with the dimensions of 2400 × 600 mm; A2: shear wall was the same as A1 wall, with the difference that the brick is installed in two stages; B1 and B2: B1 and B2 shear walls were made of steel frames with dimensions of 2400 × 1200 mm; C1 and C2 Shear walls are similar to B1 and B2 walls, the difference is that in these walls, all the space inside the frame was filled with expanded polystyrene plates and mortar was applied outside the frame and on it were made using CFSF, cement sand mortar, wire mesh, expanded polystyrene, automatic screw, ceramic and clay brick. After processing in the laboratory, these walls were subjected to seismic loading. By calculating the over-strength factor and ductility reduction factor using experimental results, it was determined that building the wall in one step (A1 compared to A2) and increasing the distance between the studs (B1 and B2 compared to A1) would increase the shear strength, but this does not cause a significant change in the behavior factor. Also, using the two methods of Uang and Pauli to calculate the behavior factor leads to almost the same results.

Authors

Institutions

Publication Details

Journal
Revista de ingeniería de construcción
Published
2025-08-01
DOI
https://doi.org/10.7764/ric.00150.21
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An analysis of seismic behavior of brick shear wall in cold-formed steel frame

Mohammad Reza Javaheri Tafti, Ahmad Fallah, Mohammad Ali Esmaili-Tafti
Revista de ingeniería de construcción
Structural Load-Bearing Analysis
article

An analysis of seismic behavior of brick shear wall in cold-formed steel frame

Mohammad Reza Javaheri Tafti, Ahmad Fallah, Mohammad Ali Esmaili-Tafti
article en

Abstract

The light steel frame system is a new construction technology system and is more economical than other construction methods due to its lightness, ease of installation, high execution speed, and ease of repair. In this article, for the first time, the effect of stud spacing and execution method on the seismic behavior of brick shear walls in a cold-formed steel frame (CFSF) was investigated. For this purpose, 6 shear walls, A1: shear wall was made of steel frame with the dimensions of 2400 × 600 mm; A2: shear wall was the same as A1 wall, with the difference that the brick is installed in two stages; B1 and B2: B1 and B2 shear walls were made of steel frames with dimensions of 2400 × 1200 mm; C1 and C2 Shear walls are similar to B1 and B2 walls, the difference is that in these walls, all the space inside the frame was filled with expanded polystyrene plates and mortar was applied outside the frame and on it were made using CFSF, cement sand mortar, wire mesh, expanded polystyrene, automatic screw, ceramic and clay brick. After processing in the laboratory, these walls were subjected to seismic loading. By calculating the over-strength factor and ductility reduction factor using experimental results, it was determined that building the wall in one step (A1 compared to A2) and increasing the distance between the studs (B1 and B2 compared to A1) would increase the shear strength, but this does not cause a significant change in the behavior factor. Also, using the two methods of Uang and Pauli to calculate the behavior factor leads to almost the same results.

Revista de ingeniería de construcciónVol. 40(2)
Islamic Azad University Maybod (IR), Islamic Azad University, Yazd (IR)
Openalex Percentile: Top 79%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An analysis of seismic behavior of brick shear wall in cold-formed steel frame — Mohammad Reza Javaheri Tafti, Ahmad Fallah, et al. · Revista de ingeniería de construcción (2025) | TGRS Research Map | TGRS