Design of Remote Lithium Battery Power Detection and Power Control System

The power input of intelligent application systems generally requires 5V2A. For some application scenarios, a dual power supply mode is adopted, including the main power supply and lithium battery. Under the control of a single-chip microcomputer, the dual power supply mode is automatically switched. The output voltage, current, and power of the power system, as well as the voltage and capacity data of the lithium battery, are measured. The measurement data is remotely sent through the Alibaba Cloud platform, and commands sent by users are received to achieve data transmission and remote power control. Special battery capacity measurement chip MAX17048 and bus voltage and load current measurement chip INA226 are used, making the circuit simple, reliable, and accurate in measurement. The system fully realizes remote data measurement and control, and has practical value.

Authors

Institutions

Publication Details

Published
2025-07-11
DOI
https://doi.org/10.1109/eicct65471.2025.11099666
Primary Topic
Embedded Systems and FPGA Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Remote Lithium Battery Power Detection and Power Control System

Jingbo Liu
Embedded Systems and FPGA Design
article

Design of Remote Lithium Battery Power Detection and Power Control System

Jingbo Liu
article en

Abstract

The power input of intelligent application systems generally requires 5V2A. For some application scenarios, a dual power supply mode is adopted, including the main power supply and lithium battery. Under the control of a single-chip microcomputer, the dual power supply mode is automatically switched. The output voltage, current, and power of the power system, as well as the voltage and capacity data of the lithium battery, are measured. The measurement data is remotely sent through the Alibaba Cloud platform, and commands sent by users are received to achieve data transmission and remote power control. Special battery capacity measurement chip MAX17048 and bus voltage and load current measurement chip INA226 are used, making the circuit simple, reliable, and accurate in measurement. The system fully realizes remote data measurement and control, and has practical value.

Nanjing Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 77%
Embedded Systems and FPGA Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.