Tactile Intelligence Enabled Pulse Oximeter for Motion Artifacts Removal

SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> is one of the most important vital signs. Photoplethysmography (PPG) is commonly used for SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> monitoring. However, motion artifacts caused by mechanical noise between the wearable device and the measurement site can affect the signal quality of PPG signals. Here, We developed a Tactile Intelligence enabled Pulse Oximeter (TIPO) with a data-driven encoder-decoder model for accurate SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> monitoring. The system integrates a flexible iontronic interface sensor with a micro PPG module. Tests during exercise showed the performance of TIPO is comparable to medical-grade equipment, with 8 times lower standard error than commercial device, demonstrating the potential of wearable flexible sensors and AI for optimized SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> monitoring in motion artifacts removal.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/fleps65444.2025.11105693
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tactile Intelligence Enabled Pulse Oximeter for Motion Artifacts Removal

Siyuan Zhou, Lei Zhao, Jiayuan Fang, Tingrui Pan
Non-Invasive Vital Sign Monitoring
article

Tactile Intelligence Enabled Pulse Oximeter for Motion Artifacts Removal

Siyuan Zhou, Lei Zhao, Jiayuan Fang, Tingrui Pan
article en

Abstract

SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> is one of the most important vital signs. Photoplethysmography (PPG) is commonly used for SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> monitoring. However, motion artifacts caused by mechanical noise between the wearable device and the measurement site can affect the signal quality of PPG signals. Here, We developed a Tactile Intelligence enabled Pulse Oximeter (TIPO) with a data-driven encoder-decoder model for accurate SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> monitoring. The system integrates a flexible iontronic interface sensor with a micro PPG module. Tests during exercise showed the performance of TIPO is comparable to medical-grade equipment, with 8 times lower standard error than commercial device, demonstrating the potential of wearable flexible sensors and AI for optimized SpO<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> monitoring in motion artifacts removal.

University of Science and Technology of China (CN), Chinese University of Hong Kong (HK), Suzhou University of Science and Technology (CN), Suzhou Research Institute (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 81%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Tactile Intelligence Enabled Pulse Oximeter for Motion Artifacts Removal — Siyuan Zhou, Lei Zhao, et al. · (2025) | TGRS Research Map | TGRS