Wearable Interdigitated Capacitive Sensor with Flexible Analog Front End for Superficial Skin Hydration Measurements

Wearable sensors and e-textiles have had an impact on many fields of healthcare, including dermatology. Superficial skin hydration is a biomarker for conditions like atopic dermatitis (AD), yet most hydration sensors are not optimised for measurement in the outermost layer of the skin - the stratum corneum (SC). In this paper, the authors present an interdigitated capacitor (IDC), tailored specifically for monitoring the shallow SC layer. The sensor is printed onto a wearable textile strap and is complemented by a custom flexible analog front end (AFE) to allow for continuous monitoring of the SC. The IDC is tested on volunteers, and the results reveal a 7% change in capacitance between skin with dry SC layer and skin with hydrated SC layer. The sensor can also be used to monitor treatments and shows that a particular commercial cream's effect wears off after 2.5 hours. The e-textile IDC can also survive a standard ISO wash test with limited electrical defects.

Authors

Institutions

Publication Details

Published
2025-06-22
DOI
https://doi.org/10.1109/fleps65444.2025.11105652
Citations
1
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Interdigitated Capacitive Sensor with Flexible Analog Front End for Superficial Skin Hydration Measurements

Huanghao Dai, Steve Beeby, Russel Torah, Michael R. Ardern‐Jones et al.
1 citations
Advanced Sensor and Energy Harvesting Materials
0.67
article

Wearable Interdigitated Capacitive Sensor with Flexible Analog Front End for Superficial Skin Hydration Measurements

Huanghao Dai, Steve Beeby, Russel Torah, Michael R. Ardern‐Jones, Alexandar R. Todorov
article en
1 citations

Abstract

Wearable sensors and e-textiles have had an impact on many fields of healthcare, including dermatology. Superficial skin hydration is a biomarker for conditions like atopic dermatitis (AD), yet most hydration sensors are not optimised for measurement in the outermost layer of the skin - the stratum corneum (SC). In this paper, the authors present an interdigitated capacitor (IDC), tailored specifically for monitoring the shallow SC layer. The sensor is printed onto a wearable textile strap and is complemented by a custom flexible analog front end (AFE) to allow for continuous monitoring of the SC. The IDC is tested on volunteers, and the results reveal a 7% change in capacitance between skin with dry SC layer and skin with hydrated SC layer. The sensor can also be used to monitor treatments and shows that a particular commercial cream's effect wears off after 2.5 hours. The e-textile IDC can also survive a standard ISO wash test with limited electrical defects.

University of Southampton (GB)
Royal Academy of Engineering, Engineering and Physical Sciences Research Council
Affordable and clean energy
Openalex Percentile: Top 28%
Advanced Sensor and Energy Harvesting Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wearable Interdigitated Capacitive Sensor with Flexible Analog Front End for Superficial Skin Hydration Measurements — Huanghao Dai, Steve Beeby, et al. · (2025) | TGRS Research Map | TGRS