Performance Analysis and Design Optimization of Wearable RFID Sensor-Antenna System for Healthcare Applications

Real-time tracking, together with monitoring and data collection of human body signals, happens through RFID technology amalgamated with wearable electronics called wearable RFID sensors. Modern sensors find placement in clothing items as well as accessories, and they also operate beneath the skin. The sensors serve several applications across healthcare monitoring, together with asset tracking and security system functions. This article delivers an extensive examination of body-area RFID antenna design issues regarding operating frequencies with biological tissue effects and antenna performance, together with safety compliance aspects. A multicomponent antenna system works as an RFID shield and functions for Bluetooth along with Wi-Fi (2.4 GHz), and includes temperature and sweat sensors for healthcare distance monitoring. The designed antenna spans 600 MHz (2.2–2.8 GHz) within its 25 × 40 × 1.5 mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> dimensions. This antenna finds optimal application in wearable systems because it utilizes semi-flexible Rogers RT5880 substrate material. The system obtains miniaturized dimensions through the implementation of two E-shaped slots, which allow the device to operate in the desired frequency range. Stability characteristics allow the antenna to operate properly near human bodies and meet the SAR safety requirements of 1.6 W/kg at its operating frequency. Realistic performance tests produced efficient results close agreement between simulated and measured data, thus validating the design potential as a remote healthcare monitoring solution.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3596519
Citations
3
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis and Design Optimization of Wearable RFID Sensor-Antenna System for Healthcare Applications

Sultan Shoaib, Waqas Ali, Muhammad Zahid, Nizamuddin Nizamuddin
3 citations
IEEE Access
Wireless Body Area Networks
2.02
article

Performance Analysis and Design Optimization of Wearable RFID Sensor-Antenna System for Healthcare Applications

Sultan Shoaib, Waqas Ali, Muhammad Zahid, Nizamuddin Nizamuddin
article en
3 citations

Abstract

Real-time tracking, together with monitoring and data collection of human body signals, happens through RFID technology amalgamated with wearable electronics called wearable RFID sensors. Modern sensors find placement in clothing items as well as accessories, and they also operate beneath the skin. The sensors serve several applications across healthcare monitoring, together with asset tracking and security system functions. This article delivers an extensive examination of body-area RFID antenna design issues regarding operating frequencies with biological tissue effects and antenna performance, together with safety compliance aspects. A multicomponent antenna system works as an RFID shield and functions for Bluetooth along with Wi-Fi (2.4 GHz), and includes temperature and sweat sensors for healthcare distance monitoring. The designed antenna spans 600 MHz (2.2–2.8 GHz) within its 25 × 40 × 1.5 mm<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> dimensions. This antenna finds optimal application in wearable systems because it utilizes semi-flexible Rogers RT5880 substrate material. The system obtains miniaturized dimensions through the implementation of two E-shaped slots, which allow the device to operate in the desired frequency range. Stability characteristics allow the antenna to operate properly near human bodies and meet the SAR safety requirements of 1.6 W/kg at its operating frequency. Realistic performance tests produced efficient results close agreement between simulated and measured data, thus validating the design potential as a remote healthcare monitoring solution.

IEEE AccessVol. 13
University of Engineering and Technology Taxila (PK), Gulf University for Science & Technology (KW), HITEC University (PK)
Affordable and clean energy
Openalex Percentile: Top 13%
Wireless Body Area Networks
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Analysis and Design Optimization of Wearable RFID Sensor-Antenna System for Healthcare Applications — Sultan Shoaib, Waqas Ali, et al. · IEEE Access (2025) | TGRS Research Map | TGRS