A Data-Driven Approach to Estimate Changes in Peak Knee Contact Force With Exoskeleton Assistance

Lower-limb exoskeletons could benefit individuals with knee osteoarthritis by reducing knee loading. Real-time estimation of knee loads could accelerate the development of load-reducing exoskeletons. However, measuring or estimating internal knee forces remains challenging due to the rarity of force-sensing knee implants and complexity of simulation-based methods. We developed two data-driven models to separately estimate the peaks in knee contact force during early and late stance using a limited set of features from electromyography (EMG), ground reaction force (GRF), and knee angle recordings. These models were trained on experimental data from healthy young adults (N = 6) walking with a wide range of knee-ankle exoskeleton torque assistance conditions. Peak knee contact forces were obtained from EMG-informed musculoskeletal simulations in OpenSim Moco. The data-driven models were evaluated using leave-one-subject-out cross validation on their ability to accurately compare exoskeleton assistance conditions. The data-driven models identified directional changes in peak knee contact force larger than 0.1 body weights (BW) with 90% accuracy for early-stance peak and 79% accuracy for late-stance peak. Both models included GRF and knee angle features, but EMG features reflected phase-specific muscle activity: quadriceps appeared in the early-stance model, plantar flexors in late stance, and hamstrings in both. We developed a simple method to rapidly estimate changes in peak knee contact force. This approach is suitable for systematic interventions that aim to reduce knee load, such as human-in-the-loop optimization of exoskeleton assistance.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2025-01-01
DOI
https://doi.org/10.1109/tnsre.2025.3596261
Citations
1
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
2.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Data-Driven Approach to Estimate Changes in Peak Knee Contact Force With Exoskeleton Assistance

Steven H. Collins, Nicholas A. Bianco, Delaney E. Miller, Ashley E. Brown et al.
1 citations
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Total Knee Arthroplasty Outcomes
2.01
article

A Data-Driven Approach to Estimate Changes in Peak Knee Contact Force With Exoskeleton Assistance

Steven H. Collins, Nicholas A. Bianco, Delaney E. Miller, Ashley E. Brown, Scott L. Delp
article en
1 citations

Abstract

Lower-limb exoskeletons could benefit individuals with knee osteoarthritis by reducing knee loading. Real-time estimation of knee loads could accelerate the development of load-reducing exoskeletons. However, measuring or estimating internal knee forces remains challenging due to the rarity of force-sensing knee implants and complexity of simulation-based methods. We developed two data-driven models to separately estimate the peaks in knee contact force during early and late stance using a limited set of features from electromyography (EMG), ground reaction force (GRF), and knee angle recordings. These models were trained on experimental data from healthy young adults (N = 6) walking with a wide range of knee-ankle exoskeleton torque assistance conditions. Peak knee contact forces were obtained from EMG-informed musculoskeletal simulations in OpenSim Moco. The data-driven models were evaluated using leave-one-subject-out cross validation on their ability to accurately compare exoskeleton assistance conditions. The data-driven models identified directional changes in peak knee contact force larger than 0.1 body weights (BW) with 90% accuracy for early-stance peak and 79% accuracy for late-stance peak. Both models included GRF and knee angle features, but EMG features reflected phase-specific muscle activity: quadriceps appeared in the early-stance model, plantar flexors in late stance, and hamstrings in both. We developed a simple method to rapidly estimate changes in peak knee contact force. This approach is suitable for systematic interventions that aim to reduce knee load, such as human-in-the-loop optimization of exoskeleton assistance.

IEEE Transactions on Neural Systems and Rehabilitation EngineeringVol. 33
Stanford Medicine (US), Stanford University (US)
Stanford Bio-X
Climate action
Openalex Percentile: Top 13%
Total Knee Arthroplasty Outcomes
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.