Quantitative Analysis of Operator Influence on IEC 61000-4-2 Indirect ESD Testing and Recommendations for Enhanced Reproducibility
The reproducibility of system-level electrostatic discharge (ESD) testing per IEC 61000-4-2 remains challenged by waveform variability, notably in the second peak region, partly due to human operator influence. Although recent Standard revisions introduce parameters like I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">P2</sub>, operator effects during indirect discharges are still unaddressed. This study examines human presence impacts on ESD waveforms during indirect discharges to horizontal and vertical coupling planes, using a SpaceWire link as the device under test. Injected and shield currents were measured under various operator conditions, alongside tests in operator-free setups with different grounding cable arrangements and protective bodywear. Results confirm significant operator-induced waveform alterations. While operator-free setups reduce variability, grounding cable layout remains crucial. Standardized, operator-free configurations with defined grounding are recommended. Where manual operation is unavoidable, ESD gloves and shoes partially improve test consistency.
Authors
- Eleni P. Nicolopoulou (ORCID: https://orcid.org/0000-0003-4071-5185)
- Christos A. Christodoulou (ORCID: https://orcid.org/0000-0001-9660-3049)
- Panagiotis K. Papastamatis (ORCID: https://orcid.org/0000-0002-5988-9583)
- Ioannis F. Gonos (ORCID: https://orcid.org/0000-0001-6743-4784)
Institutions
- National Technical University of Athens (GR)
Publication Details
- Journal
- IEEE Access
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/access.2025.3596287
- Primary Topic
- Electrostatic Discharge in Electronics
- Type
- article
- Field-Weighted Citation Impact
- 0.00