Quantitative Analysis of Operator Influence on IEC 61000-4-2 Indirect ESD Testing and Recommendations for Enhanced Reproducibility

The reproducibility of system-level electrostatic discharge (ESD) testing per IEC 61000-4-2 remains challenged by waveform variability, notably in the second peak region, partly due to human operator influence. Although recent Standard revisions introduce parameters like I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">P2</sub>, operator effects during indirect discharges are still unaddressed. This study examines human presence impacts on ESD waveforms during indirect discharges to horizontal and vertical coupling planes, using a SpaceWire link as the device under test. Injected and shield currents were measured under various operator conditions, alongside tests in operator-free setups with different grounding cable arrangements and protective bodywear. Results confirm significant operator-induced waveform alterations. While operator-free setups reduce variability, grounding cable layout remains crucial. Standardized, operator-free configurations with defined grounding are recommended. Where manual operation is unavoidable, ESD gloves and shoes partially improve test consistency.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3596287
Primary Topic
Electrostatic Discharge in Electronics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Analysis of Operator Influence on IEC 61000-4-2 Indirect ESD Testing and Recommendations for Enhanced Reproducibility

Eleni P. Nicolopoulou, Christos A. Christodoulou, Panagiotis K. Papastamatis, Ioannis F. Gonos
IEEE Access
Electrostatic Discharge in Electronics
article

Quantitative Analysis of Operator Influence on IEC 61000-4-2 Indirect ESD Testing and Recommendations for Enhanced Reproducibility

Eleni P. Nicolopoulou, Christos A. Christodoulou, Panagiotis K. Papastamatis, Ioannis F. Gonos
article en

Abstract

The reproducibility of system-level electrostatic discharge (ESD) testing per IEC 61000-4-2 remains challenged by waveform variability, notably in the second peak region, partly due to human operator influence. Although recent Standard revisions introduce parameters like I<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">P2</sub>, operator effects during indirect discharges are still unaddressed. This study examines human presence impacts on ESD waveforms during indirect discharges to horizontal and vertical coupling planes, using a SpaceWire link as the device under test. Injected and shield currents were measured under various operator conditions, alongside tests in operator-free setups with different grounding cable arrangements and protective bodywear. Results confirm significant operator-induced waveform alterations. While operator-free setups reduce variability, grounding cable layout remains crucial. Standardized, operator-free configurations with defined grounding are recommended. Where manual operation is unavoidable, ESD gloves and shoes partially improve test consistency.

IEEE AccessVol. 13
National Technical University of Athens (GR)
Openalex Percentile: Top 82%
Electrostatic Discharge in Electronics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.