Improved Non-Invasive Blood Glucose Monitoring

This research investigates the design and performance of non-invasive blood glucose sensors using microwave resonators with two different permittivity substrates, Rogers 4360 G 2 (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=6.15$</tex>) and Rogers 4003C (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=3.38$</tex>). Numerical simulations conducted with the CST Microwave Studio electromagnetic solver were used to analyze the sensors' sensitivity and losses. The results demonstrated that the sensor with higher permittivity (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=6.15$</tex>) exhibited greater sensitivity (1.1 dB per mg/dL) and lower losses (0.55) compared to the sensor with lower permittivity (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=3.38$</tex>), which showed a sensitivity of 0.08 dB per mg/dL and losses of 0.68. These findings suggest that the sensor with higher permittivity is more effective for continuous glucose monitoring due to its superior sensitivity and efficiency.

Authors

Institutions

Publication Details

Published
2024-08-11
DOI
https://doi.org/10.1109/mwscas60917.2024.11113408
Citations
1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.66
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Non-Invasive Blood Glucose Monitoring

Ahmed Allam, Ahmed A. Zakaria, Tanemasa Asano, Adel B. Abdel-Rahman
1 citations
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
article

Improved Non-Invasive Blood Glucose Monitoring

Ahmed Allam, Ahmed A. Zakaria, Tanemasa Asano, Adel B. Abdel-Rahman
article en
1 citations

Abstract

This research investigates the design and performance of non-invasive blood glucose sensors using microwave resonators with two different permittivity substrates, Rogers 4360 G 2 (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=6.15$</tex>) and Rogers 4003C (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=3.38$</tex>). Numerical simulations conducted with the CST Microwave Studio electromagnetic solver were used to analyze the sensors' sensitivity and losses. The results demonstrated that the sensor with higher permittivity (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=6.15$</tex>) exhibited greater sensitivity (1.1 dB per mg/dL) and lower losses (0.55) compared to the sensor with lower permittivity (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\varepsilon=3.38$</tex>), which showed a sensitivity of 0.08 dB per mg/dL and losses of 0.68. These findings suggest that the sensor with higher permittivity is more effective for continuous glucose monitoring due to its superior sensitivity and efficiency.

Kyushu University (JP), Egypt-Japan University of Science and Technology (EG)
Zero hunger
Openalex Percentile: Top 18%
Spectroscopy Techniques in Biomedical and Chemical Research
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.