Fuzzy Logic with PI Controller and Multivariable Filter for Harmonic Reduction Based Hybrid Active Power Filter

In this paper, a Fuzzy Logic used with Proportional Integral (PI) controller to regulate the DC bus voltage of Hybrid Power Filter (HPF) in order to improve power quality of the three-phase distribution system. The electricals and electronics equipment generate a large quantity of harmonics currents which effects several problems in the supply system. The principal goal of this study is to improve the efficiency of HPF, suppress harmonics currents and consequently reduce Total Harmonic Distortion (THD) under 5%. The suggested control mechanism is d-q theory based on Multivariable Filter (MF) and Fuzzy Logic for extracting reference currents. The efficiency of combined fuzzy logic and PI controller is evaluated by the simulation study using Matlab/Simulink software and the obtained results are presented.

Authors

Publication Details

Journal
المجلة الدولية للعلوم الهندسية وتقنية المعلومات.
Published
2025-05-31
DOI
https://doi.org/10.36602/ijeit.v13i2.554
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fuzzy Logic with PI Controller and Multivariable Filter for Harmonic Reduction Based Hybrid Active Power Filter

Tareq Elgargani, Mohamed Abdusalam
المجلة الدولية للعلوم الهندسية وتقنية المعلومات.
Power Quality and Harmonics
article

Fuzzy Logic with PI Controller and Multivariable Filter for Harmonic Reduction Based Hybrid Active Power Filter

Tareq Elgargani, Mohamed Abdusalam
article en

Abstract

In this paper, a Fuzzy Logic used with Proportional Integral (PI) controller to regulate the DC bus voltage of Hybrid Power Filter (HPF) in order to improve power quality of the three-phase distribution system. The electricals and electronics equipment generate a large quantity of harmonics currents which effects several problems in the supply system. The principal goal of this study is to improve the efficiency of HPF, suppress harmonics currents and consequently reduce Total Harmonic Distortion (THD) under 5%. The suggested control mechanism is d-q theory based on Multivariable Filter (MF) and Fuzzy Logic for extracting reference currents. The efficiency of combined fuzzy logic and PI controller is evaluated by the simulation study using Matlab/Simulink software and the obtained results are presented.

المجلة الدولية للعلوم الهندسية وتقنية المعلومات.Vol. 13(2)
Openalex Percentile: Top 82%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.