Numerical analysis of the acoustic pressure inside blood vessel with exposure to high-intensity focused ultrasound

This study investigates acoustic pressure distribution in blood vessels under high-intensity focused ultrasound (HIFU) for sonothrombolysis (STL). A tissue-mimicking phantom (skin, fat, muscle, blood) was modeled, and pressure was calculated using the Westervelt equation. Results show peak pressure increases with frequency (0.5-2 MHz), while attenuation intensifies with higher power, frequency, and vessel depth (10-30 mm). Frequencies above 1.1 MHz caused greater attenuation, influenced by skin (1-5 mm) and fat (2-7 mm) thicknesses. Below 1.1 MHz, consistent HIFU power yields similar clinical outcomes across patients, aiding STL treatment optimization.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-08-04
DOI
https://doi.org/10.1080/10255842.2025.2541896
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical analysis of the acoustic pressure inside blood vessel with exposure to high-intensity focused ultrasound

Jonghyok Ri, Insong Kim, Na Pang, Vincent Ji et al.
Computer Methods in Biomechanics & Biomedical Engineering
Ultrasound and Hyperthermia Applications
article

Numerical analysis of the acoustic pressure inside blood vessel with exposure to high-intensity focused ultrasound

Jonghyok Ri, Insong Kim, Na Pang, Vincent Ji, Xiangji Yue, Lisheng Xu, Dingchang Zheng, Li Shen
article en

Abstract

This study investigates acoustic pressure distribution in blood vessels under high-intensity focused ultrasound (HIFU) for sonothrombolysis (STL). A tissue-mimicking phantom (skin, fat, muscle, blood) was modeled, and pressure was calculated using the Westervelt equation. Results show peak pressure increases with frequency (0.5-2 MHz), while attenuation intensifies with higher power, frequency, and vessel depth (10-30 mm). Frequencies above 1.1 MHz caused greater attenuation, influenced by skin (1-5 mm) and fat (2-7 mm) thicknesses. Below 1.1 MHz, consistent HIFU power yields similar clinical outcomes across patients, aiding STL treatment optimization.

Computer Methods in Biomechanics & Biomedical Engineering
Hebei Medical University (CN), Northeastern University (US), Ministry of Education of the People's Republic of China (CN), Sun Yat-sen University (CN), Fudan University (CN), Zhongshan Hospital (CN), The First Affiliated Hospital, Sun Yat-sen University (CN), Shenzhen Institutes of Advanced Technology (CN), Intelligent Health (United Kingdom) (GB), Coventry University (GB), Universidad del Noreste (MX), Northeastern University (CN)
National Natural Science Foundation of China, Natural Science Foundation of Liaoning Province
Openalex Percentile: Top 82%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical analysis of the acoustic pressure inside blood vessel with exposure to high-intensity focused ultrasound — Jonghyok Ri, Insong Kim, et al. · Computer Methods in Biomechanics & Biomedical Engineering (2025) | TGRS Research Map | TGRS