Impacts of ventilation layouts on dust dispersion and particulate exposure in deep mining: A study within a full-scale heading face

Deep coal mining operates in increasingly extreme environments, where substantial dust generated during the mining process poses serious risks to both production safety and miners' health. To understand the dust transport pattern and miners' particulate exposure risk within a full-scale heading face under various ventilation configurations, airflow patterns and dust dispersion characteristics were systematically investigated using the Euler–Lagrangian approach. A user-defined function was developed to enable the dynamic injection of particles, simulating realistic dust generation processes. The average residence times of particles with varying sizes were calculated, and the number of particles entering the respiratory zone was quantified to assess the driver's exposure risk. Results revealed that the driver remained in the recirculation zone in all layouts. The centrally positioned ventilation cylinder facilitated the suspension of smaller particles. With a total suspension time of 300 s and an air supply velocity of 11 m/s, particles sized below 20 µm exhibited the longest average residence time—11.24% and 26.24% longer than in layout R (cylinder on the opposite side of the driver) and layout L (cylinder on the driver's side), respectively. Smaller respiratory dust (i.e., dp < 7.07 µm) and particles originating from the upper part of the dust injection surface were most likely to enter the driver's respiratory zone. Increasing the fresh air supply alone proved insufficient to reduce particulate exposure. Among the configurations, layout L was optimal, reducing particulate exposure by 65.12% compared to layout R. This study provides theoretical insights for optimizing ventilation strategies within the heading face.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0276290
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impacts of ventilation layouts on dust dispersion and particulate exposure in deep mining: A study within a full-scale heading face

Rong Xu, Xueren Li, Jiaqi Fan, Changgeng Gui et al.
Physics of Fluids
Cyclone Separators and Fluid Dynamics
article

Impacts of ventilation layouts on dust dispersion and particulate exposure in deep mining: A study within a full-scale heading face

Rong Xu, Xueren Li, Jiaqi Fan, Changgeng Gui, Zhengbiao Peng, Xinjian He, Shihang Li, Zhaoxing Li, Fan Geng
article en

Abstract

Deep coal mining operates in increasingly extreme environments, where substantial dust generated during the mining process poses serious risks to both production safety and miners' health. To understand the dust transport pattern and miners' particulate exposure risk within a full-scale heading face under various ventilation configurations, airflow patterns and dust dispersion characteristics were systematically investigated using the Euler–Lagrangian approach. A user-defined function was developed to enable the dynamic injection of particles, simulating realistic dust generation processes. The average residence times of particles with varying sizes were calculated, and the number of particles entering the respiratory zone was quantified to assess the driver's exposure risk. Results revealed that the driver remained in the recirculation zone in all layouts. The centrally positioned ventilation cylinder facilitated the suspension of smaller particles. With a total suspension time of 300 s and an air supply velocity of 11 m/s, particles sized below 20 µm exhibited the longest average residence time—11.24% and 26.24% longer than in layout R (cylinder on the opposite side of the driver) and layout L (cylinder on the driver's side), respectively. Smaller respiratory dust (i.e., dp < 7.07 µm) and particles originating from the upper part of the dust injection surface were most likely to enter the driver's respiratory zone. Increasing the fresh air supply alone proved insufficient to reduce particulate exposure. Among the configurations, layout L was optimal, reducing particulate exposure by 65.12% compared to layout R. This study provides theoretical insights for optimizing ventilation strategies within the heading face.

Physics of FluidsVol. 37(8)
Xuzhou University of Technology (CN), China University of Mining and Technology (CN), MIT University (MK), J.M. Burgerscentrum (NL), RMIT University (AU)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 79%
Cyclone Separators and Fluid Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.