Assessment of overall essential tremor severity by monitoring with a wearable inertial sensor in real-life settings: an exploratory study

<h2>Abstract</h2><h3>Background</h3> Wearable digital technologies enable the objective monitoring and quantification of essential tremor (ET) in a real-world setting. <h3>Objective</h3> To quantify the overall severity of ET through continuous home monitoring using a wearable inertial sensor. <h3>Methods</h3> Twelve ET patients were monitored with an inertial sensor embedded in a smartwatch for an average of 11.61 ± 1.99 h per day over 6.67 ± 2.19 days. Overall tremor severity was defined based on the daily quantification of mild, moderate or severe tremor. Two scenarios were considered: 10 % (1) or 15 % (2) of the daily monitored time with higher tremor severity established the overall tremor severity, which was compared (Cohen's k) with that provided by the neurologists' assessment at the hospital and the patients' self-assessment at home using the Fahn Tolosa Marin Tremor Rating Scale. The effect of treatment on tremor severity was quantified using sensor data collected from eight patients. <h3>Results</h3> No or insignificant agreement was found between the overall tremor severity defined by continuous monitoring and that determined by the neurologist's assessment (Cohen's k = −0.113 and −0.277 for 10 % and 15 % scenarios, respectively) or patient self-assessment (Cohen's k = 0.133 and 0.168 for 10 % and 15 % scenarios, respectively). Neurologists underestimated the overall tremor severity with respect to continuous monitoring and patient self-assessment. Treatment was associated with a significant reduction in time with moderate (p = 0.034) and with moderate to severe (p = 0.027) tremor. <h3>Conclusions</h3> Continuous monitoring of ET with a wearable sensor provides more objective information about the overall tremor severity in a real-world setting and could more accurately quantify the response to treatment.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2025-08-01
DOI
https://doi.org/10.1016/j.heliyon.2025.e43707
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of overall essential tremor severity by monitoring with a wearable inertial sensor in real-life settings: an exploratory study

Alba Vieira-Campos, Yolanda Aladro, Guillermo Martín-Ávila, Joaquín Ordieres‐Meré et al.
Heliyon
Neurological disorders and treatments
article

Assessment of overall essential tremor severity by monitoring with a wearable inertial sensor in real-life settings: an exploratory study

Alba Vieira-Campos, Yolanda Aladro, Guillermo Martín-Ávila, Joaquín Ordieres‐Meré, Israel J. Thuissard, Cristina Andreu‐Vázquez, Sergio Labrador-Marcos, Xiaochen Zheng, Alejandro Méndez-Burgos
article en

Abstract

<h2>Abstract</h2><h3>Background</h3> Wearable digital technologies enable the objective monitoring and quantification of essential tremor (ET) in a real-world setting. <h3>Objective</h3> To quantify the overall severity of ET through continuous home monitoring using a wearable inertial sensor. <h3>Methods</h3> Twelve ET patients were monitored with an inertial sensor embedded in a smartwatch for an average of 11.61 ± 1.99 h per day over 6.67 ± 2.19 days. Overall tremor severity was defined based on the daily quantification of mild, moderate or severe tremor. Two scenarios were considered: 10 % (1) or 15 % (2) of the daily monitored time with higher tremor severity established the overall tremor severity, which was compared (Cohen's k) with that provided by the neurologists' assessment at the hospital and the patients' self-assessment at home using the Fahn Tolosa Marin Tremor Rating Scale. The effect of treatment on tremor severity was quantified using sensor data collected from eight patients. <h3>Results</h3> No or insignificant agreement was found between the overall tremor severity defined by continuous monitoring and that determined by the neurologist's assessment (Cohen's k = −0.113 and −0.277 for 10 % and 15 % scenarios, respectively) or patient self-assessment (Cohen's k = 0.133 and 0.168 for 10 % and 15 % scenarios, respectively). Neurologists underestimated the overall tremor severity with respect to continuous monitoring and patient self-assessment. Treatment was associated with a significant reduction in time with moderate (p = 0.034) and with moderate to severe (p = 0.027) tremor. <h3>Conclusions</h3> Continuous monitoring of ET with a wearable sensor provides more objective information about the overall tremor severity in a real-world setting and could more accurately quantify the response to treatment.

HeliyonVol. 11(13)
Southern University of Science and Technology (CN), Hospital Universitario de Getafe (ES), Hospital Universitario de La Princesa (ES), Hospital Universitario de Fuenlabrada (ES), Universidad Politécnica de Madrid (ES), Universidad Europea de Madrid (ES)
Climate action
Openalex Percentile: Top 71%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.