A System-Agnostic Process to Design DC Series Arc Fault Detectors

Researchers are developing and testing electrified aircraft propulsion (EAP) systems which promise to stimulate new markets and missions, reduce operating costs, and increase efficiency. High-voltage direct current (HVDC) power systems are especially attractive for EAP because high voltages are required to minimize cable mass for desired operating power levels, and DC architectures enable both simpler control schemes and easier integration of sources and loads. On the other hand, electric arcs are more destructive at high powers and more likely to form at high voltages and altitudes. Furthermore, DC arcs formed by an interruption in a single electrical wire (series arcs) can resemble other spurious events such as switching noise. It is crucial both to the aircraft and to passenger safety to detect and isolate this species of arc fault, but doing so poses a non-trivial problem: DC arcs do not have a zero-crossing to facilitate their quenching, and classical overcurrent protection methods fail to detect them. This paper outlines a method of designing series arc fault detection algorithms by collecting arc test data, building a model of the power system, and optimizing arc detector parameters and structures to maximize accuracy and minimize latency as tested against the model. Interpretable machine learning optimization techniques and detectors were employed because they have a more assured and simpler path to aerospace flight certification than black box algorithms. Arcs were generated on a 28 VDC testbench, a circuit model and redundant arc detectors were designed, and one candidate detector solution was implemented in a field-programmable gate array (FPGA) and tested against live arcs.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/itec63604.2025.11098162
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A System-Agnostic Process to Design DC Series Arc Fault Detectors

Trey D. Rupp, David J. Sadey, Brian P. Malone, George Thomas et al.
1 citations
Electrical Fault Detection and Protection
0.73
article

A System-Agnostic Process to Design DC Series Arc Fault Detectors

Trey D. Rupp, David J. Sadey, Brian P. Malone, George Thomas, Bryce A. Lanese
article en
1 citations

Abstract

Researchers are developing and testing electrified aircraft propulsion (EAP) systems which promise to stimulate new markets and missions, reduce operating costs, and increase efficiency. High-voltage direct current (HVDC) power systems are especially attractive for EAP because high voltages are required to minimize cable mass for desired operating power levels, and DC architectures enable both simpler control schemes and easier integration of sources and loads. On the other hand, electric arcs are more destructive at high powers and more likely to form at high voltages and altitudes. Furthermore, DC arcs formed by an interruption in a single electrical wire (series arcs) can resemble other spurious events such as switching noise. It is crucial both to the aircraft and to passenger safety to detect and isolate this species of arc fault, but doing so poses a non-trivial problem: DC arcs do not have a zero-crossing to facilitate their quenching, and classical overcurrent protection methods fail to detect them. This paper outlines a method of designing series arc fault detection algorithms by collecting arc test data, building a model of the power system, and optimizing arc detector parameters and structures to maximize accuracy and minimize latency as tested against the model. Interpretable machine learning optimization techniques and detectors were employed because they have a more assured and simpler path to aerospace flight certification than black box algorithms. Arcs were generated on a 28 VDC testbench, a circuit model and redundant arc detectors were designed, and one candidate detector solution was implemented in a field-programmable gate array (FPGA) and tested against live arcs.

Cleveland State University (US), Glenn Research Center (US)
Openalex Percentile: Top 25%
Electrical Fault Detection and Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A System-Agnostic Process to Design DC Series Arc Fault Detectors — Trey D. Rupp, David J. Sadey, et al. · (2025) | TGRS Research Map | TGRS