Analysis of Overvoltage in Renewable Energy Integration Systems During Single-Phase Shortcircuit and Open-Phase Operation Faults

This study investigates voltage characteristics and overvoltage mechanisms in renewable energy integration systems under asymmetric fault. The circuit models for single-phase short-circuit and open-phase operation faults are established, derives analytical expressions for fault voltages, and identifies key factors influencing overvoltage. A photovoltaic (PV) integration system case study demonstrates that: (1) Increasing current limitation during single-phase faults enhances voltage support capability; (2) Reducing negative-sequence reactive current injection and active current output during open-phase operation effectively suppresses overvoltage risks; (3) The phase-locked loop (PLL) phase deviation exhibits an overvoltage amplifying effect during transient oscillations. The theoretical analysis is validated through PSCAD/EMTDC simulations, providing actionable insights for optimizing fault ride-through strategies in renewable energy systems.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/ieecsc64206.2025.11099949
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Overvoltage in Renewable Energy Integration Systems During Single-Phase Shortcircuit and Open-Phase Operation Faults

Ziqian Yang, Wangqianyun Tang, Ye Zhang, Wei Liu
Power Systems and Technologies
article

Analysis of Overvoltage in Renewable Energy Integration Systems During Single-Phase Shortcircuit and Open-Phase Operation Faults

Ziqian Yang, Wangqianyun Tang, Ye Zhang, Wei Liu
article en

Abstract

This study investigates voltage characteristics and overvoltage mechanisms in renewable energy integration systems under asymmetric fault. The circuit models for single-phase short-circuit and open-phase operation faults are established, derives analytical expressions for fault voltages, and identifies key factors influencing overvoltage. A photovoltaic (PV) integration system case study demonstrates that: (1) Increasing current limitation during single-phase faults enhances voltage support capability; (2) Reducing negative-sequence reactive current injection and active current output during open-phase operation effectively suppresses overvoltage risks; (3) The phase-locked loop (PLL) phase deviation exhibits an overvoltage amplifying effect during transient oscillations. The theoretical analysis is validated through PSCAD/EMTDC simulations, providing actionable insights for optimizing fault ride-through strategies in renewable energy systems.

China Southern Power Grid (China) (CN)
China Southern Power Grid, National Outstanding Youth Science Fund Project of National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 82%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Overvoltage in Renewable Energy Integration Systems During Single-Phase Shortcircuit and Open-Phase Operation Faults — Ziqian Yang, Wangqianyun Tang, et al. · (2025) | TGRS Research Map | TGRS