Fault Control Strategy for Torque Ripple Reduction in Single-Phase Open Fault of OW-PMSM Fed by a Dual Inverter with a Common DC Bus

Detecting and fault-tolerant control (FTC) strategy is very important to improve the reliability of the drive system. Various control strategies for zero-sequence current (ZSC) reduction have been studied for open-winding permanent magnet synchronous motor (OW-PMSM) fed by a dual inverter with a common DC bus system. However, during single-phase open faults, the use of conventional control methods for OW-PMSM results in significant torque ripple due to degradation in ZSC suppression performance. Therefore, this article proposes a method to reduce torque ripple through a novel <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$q$</tex>-axis compensation method. The proposed method can be implemented with a relatively simple modulation method during fault modes. A resonant controller is introduced to reduce second and fourth order harmonic currents. Additionally, the paper presents a fault detection method through ZSC estimation. The effectiveness of the proposed method is verified through simulation and experimental results.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/itec63604.2025.11098028
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Control Strategy for Torque Ripple Reduction in Single-Phase Open Fault of OW-PMSM Fed by a Dual Inverter with a Common DC Bus

Kibok Lee, Donghyuk Kim, Hyeonseong Kim
Multilevel Inverters and Converters
article

Fault Control Strategy for Torque Ripple Reduction in Single-Phase Open Fault of OW-PMSM Fed by a Dual Inverter with a Common DC Bus

Kibok Lee, Donghyuk Kim, Hyeonseong Kim
article en

Abstract

Detecting and fault-tolerant control (FTC) strategy is very important to improve the reliability of the drive system. Various control strategies for zero-sequence current (ZSC) reduction have been studied for open-winding permanent magnet synchronous motor (OW-PMSM) fed by a dual inverter with a common DC bus system. However, during single-phase open faults, the use of conventional control methods for OW-PMSM results in significant torque ripple due to degradation in ZSC suppression performance. Therefore, this article proposes a method to reduce torque ripple through a novel <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$q$</tex>-axis compensation method. The proposed method can be implemented with a relatively simple modulation method during fault modes. A resonant controller is introduced to reduce second and fourth order harmonic currents. Additionally, the paper presents a fault detection method through ZSC estimation. The effectiveness of the proposed method is verified through simulation and experimental results.

Korea University (KR)
National Research Foundation of Korea
Affordable and clean energy
Openalex Percentile: Top 82%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fault Control Strategy for Torque Ripple Reduction in Single-Phase Open Fault of OW-PMSM Fed by a Dual Inverter with a Common DC Bus — Kibok Lee, Donghyuk Kim, et al. · (2025) | TGRS Research Map | TGRS