Analysis and Calculation of Ac Fault Characteristics of New Energy Transmission System Through Dc

The control characteristic of the flexible DC converter station and the wind turbine grid side converter is very different from the traditional AC transmission after the AC fault occurs in the flexible DC transmission system of offshore wind power. Therefore, it is necessary to have a fault calculation. In order to solve this problem, the fault equivalent model of the whole AC system is established based on the low voltage ride through strategy and the corresponding fault calculation method is derived. Firstly, the AC fault characteristics of offshore wind power system via flexible DC are qualitatively analyzed. Then, based on the control characteristics of the system during the fault period, the fault equivalent model of the entire AC system is established, and the corresponding fault calculation formula is derived based on the fault equivalent model. Finally, the effectiveness of the proposed method is verified by PSCAD/EMTDC simulation based on the fault degree and fault location.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/ieecsc64206.2025.11099933
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Calculation of Ac Fault Characteristics of New Energy Transmission System Through Dc

Yanxun Guo, Junjie Feng, Tao Feng
Power Systems and Technologies
article

Analysis and Calculation of Ac Fault Characteristics of New Energy Transmission System Through Dc

Yanxun Guo, Junjie Feng, Tao Feng
article en

Abstract

The control characteristic of the flexible DC converter station and the wind turbine grid side converter is very different from the traditional AC transmission after the AC fault occurs in the flexible DC transmission system of offshore wind power. Therefore, it is necessary to have a fault calculation. In order to solve this problem, the fault equivalent model of the whole AC system is established based on the low voltage ride through strategy and the corresponding fault calculation method is derived. Firstly, the AC fault characteristics of offshore wind power system via flexible DC are qualitatively analyzed. Then, based on the control characteristics of the system during the fault period, the fault equivalent model of the entire AC system is established, and the corresponding fault calculation formula is derived based on the fault equivalent model. Finally, the effectiveness of the proposed method is verified by PSCAD/EMTDC simulation based on the fault degree and fault location.

Zhengzhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 82%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.