Thermal Performance Evaluation and Design Optimization of a Battery Disconnect Unit for High-Power Electric Vehicle Applications

The battery disconnect unit (BDU) is one of the most essential safety systems and battery control sub-assemblies within conventional electric vehicles (EVs) to date. The BDU plays a critical role in electro-mechanical control and protection by using contactors and fuses to manage the flow and distribution of power. The selection of busbar size and means of convection is critical given the restrictive mechanical constraints imposed by OEM battery tray designs-including requirements for vibration, electrical isolation, manufacturing tolerances, and creepages and clearances. This study aims to provide a thermally focused evaluation of various busbar thicknesses in addition to also determine whether natural convection is sufficient to manage the heat rise, or if forced convection is required using a combined joule heating modelling approach in MATLAB Simulink and computational fluid dynamics (CFD) with SolidWorks. A mixed drive cycle and constant current charging conditions were applied to determine key hotspots and assess component temperature rise. The methodology incorporates mechanical constraints, high voltage schematics, and justification of electrical component selection to provide a practical and thermally reliable custom BDU. Results showed that 6 mm thick C110 copper busbar limited the temperature rise under a DC fast charging (DCFC) case of 29.09° C whereas thinner busbars exceeded 30° C. Forced convection with a convection coefficient of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$35\ \mathrm{W} /\left(\mathrm{m}^{2} \cdot \mathrm{K}\right)$</tex> was superior to natural convection with a ROA for the DCFC case being 4.35° C as opposed to the natural convection case of 13.27 °C, both approaches maintained temperatures within acceptable limits. Ultimately, natural convection was selected due to its thermal adequacy and drastically lower mechanical complexity.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/itec63604.2025.11098064
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Performance Evaluation and Design Optimization of a Battery Disconnect Unit for High-Power Electric Vehicle Applications

Romulo Vieira, Phillip J. Kollmeyer, Saied Habibi, Ryan Ahmed et al.
Advanced Battery Technologies Research
article

Thermal Performance Evaluation and Design Optimization of a Battery Disconnect Unit for High-Power Electric Vehicle Applications

Romulo Vieira, Phillip J. Kollmeyer, Saied Habibi, Ryan Ahmed, Lewis Gross, Kavish Wadehra
article en

Abstract

The battery disconnect unit (BDU) is one of the most essential safety systems and battery control sub-assemblies within conventional electric vehicles (EVs) to date. The BDU plays a critical role in electro-mechanical control and protection by using contactors and fuses to manage the flow and distribution of power. The selection of busbar size and means of convection is critical given the restrictive mechanical constraints imposed by OEM battery tray designs-including requirements for vibration, electrical isolation, manufacturing tolerances, and creepages and clearances. This study aims to provide a thermally focused evaluation of various busbar thicknesses in addition to also determine whether natural convection is sufficient to manage the heat rise, or if forced convection is required using a combined joule heating modelling approach in MATLAB Simulink and computational fluid dynamics (CFD) with SolidWorks. A mixed drive cycle and constant current charging conditions were applied to determine key hotspots and assess component temperature rise. The methodology incorporates mechanical constraints, high voltage schematics, and justification of electrical component selection to provide a practical and thermally reliable custom BDU. Results showed that 6 mm thick C110 copper busbar limited the temperature rise under a DC fast charging (DCFC) case of 29.09° C whereas thinner busbars exceeded 30° C. Forced convection with a convection coefficient of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$35\ \mathrm{W} /\left(\mathrm{m}^{2} \cdot \mathrm{K}\right)$</tex> was superior to natural convection with a ROA for the DCFC case being 4.35° C as opposed to the natural convection case of 13.27 °C, both approaches maintained temperatures within acceptable limits. Ultimately, natural convection was selected due to its thermal adequacy and drastically lower mechanical complexity.

McMaster University Medical Centre (CA), McMaster University (CA)
Affordable and clean energy
Openalex Percentile: Top 80%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.