Frequency Domain Spectroscopy Characteristics of Transformer Oil-Paper Insulation Under Wide Temperature Range

As the core component in oil-immersed power transformers, oil-paper insulation exhibit dielectric properties heavily influenced by temperature-humidity coupling. This study systematically investigates the dielectric loss factor <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(tan \delta)$</tex> evolution across a broad temperature range <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\left(-20-70^{\circ} \mathrm{C}\right)$</tex> using frequency domain spectroscopy (FDS). Dry-state <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(&lt;0.5 \%$</tex> water content) and damp-state (4.2% water content) oil-paper insulation samples were prepared for analysis. Experimental results demonstrate that within the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$10 \text{mHz}-1 \text{kHz}$</tex> frequency band, tand for both dry and damp insulation rises exponentially with temperature. Notably, damp samples exhibit <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{tan} \boldsymbol{\delta}$</tex> increases 2-3 orders of magnitude greater than dry samples in low-frequency regions <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(&lt;0.1 ~\text{Hz})$</tex>, highlighting moisture's role in amplifying dielectric loss through intensified interfacial polarization and ionic conductivity. These findings establish a dielectric response database under temperature-wetness coupling, supporting transformer insulation diagnostics across diverse operating conditions.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/ieecsc64206.2025.11099762
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency Domain Spectroscopy Characteristics of Transformer Oil-Paper Insulation Under Wide Temperature Range

Zhengqin Zhou, Limin Qu, Lifeng Cheng, Peng Zhang et al.
Power Transformer Diagnostics and Insulation
article

Frequency Domain Spectroscopy Characteristics of Transformer Oil-Paper Insulation Under Wide Temperature Range

Zhengqin Zhou, Limin Qu, Lifeng Cheng, Peng Zhang, J. Andrew Zhang, Jing Zhang, Dewen Zhang
article en

Abstract

As the core component in oil-immersed power transformers, oil-paper insulation exhibit dielectric properties heavily influenced by temperature-humidity coupling. This study systematically investigates the dielectric loss factor <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(tan \delta)$</tex> evolution across a broad temperature range <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\left(-20-70^{\circ} \mathrm{C}\right)$</tex> using frequency domain spectroscopy (FDS). Dry-state <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(&lt;0.5 \%$</tex> water content) and damp-state (4.2% water content) oil-paper insulation samples were prepared for analysis. Experimental results demonstrate that within the <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$10 \text{mHz}-1 \text{kHz}$</tex> frequency band, tand for both dry and damp insulation rises exponentially with temperature. Notably, damp samples exhibit <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\boldsymbol{tan} \boldsymbol{\delta}$</tex> increases 2-3 orders of magnitude greater than dry samples in low-frequency regions <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$(&lt;0.1 ~\text{Hz})$</tex>, highlighting moisture's role in amplifying dielectric loss through intensified interfacial polarization and ionic conductivity. These findings establish a dielectric response database under temperature-wetness coupling, supporting transformer insulation diagnostics across diverse operating conditions.

State Grid Corporation of China (China) (CN), Harbin Electric Corporation (China) (CN), Heilongjiang Electric Power Workers University (CN)
Foundation for Innovative Research Groups of the National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 82%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.