DC Fault Diagnosis and Suppression Method of Dual Active Bridge Converters Based on Junction Temperature Reliability Feedback

Due to the bidirectional energy flow characteristic of the dual active bridge (DAB) converter, it is widely used in situations where electric energy needs to be transmitted back and forth, such as bidirectional energy transmission between electric vehicles and power grids. In order to improve the reliability and safety of the DAB converter, fast fault point detection and effective fault protection mechanism are crucial to improving circuit reliability. This paper proposes a fault detection and active thermal control strategy (ACT) based on junction temperature lifetime reliability feedback. It can detect whether the short circuit faults (SCFs) occurs in the secondary side silicon carbide (SiC) device by monitoring the junction temperature fluctuation of the primary side SiC device. The proposed ACT algorithm actively adjusts the circuit drive signal after the fault occurs to eliminate the fault in time. At the same time, it ensures effective fault monitoring without significantly sacrificing the lifetime of the primary side SiC devices.

Authors

Institutions

Publication Details

Published
2025-06-18
DOI
https://doi.org/10.1109/itec63604.2025.11097941
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DC Fault Diagnosis and Suppression Method of Dual Active Bridge Converters Based on Junction Temperature Reliability Feedback

Wilmar Martínez, Bangli Du, Yu Zuo, Kazim Efe Özel
High-Voltage Power Transmission Systems
article

DC Fault Diagnosis and Suppression Method of Dual Active Bridge Converters Based on Junction Temperature Reliability Feedback

Wilmar Martínez, Bangli Du, Yu Zuo, Kazim Efe Özel
article en

Abstract

Due to the bidirectional energy flow characteristic of the dual active bridge (DAB) converter, it is widely used in situations where electric energy needs to be transmitted back and forth, such as bidirectional energy transmission between electric vehicles and power grids. In order to improve the reliability and safety of the DAB converter, fast fault point detection and effective fault protection mechanism are crucial to improving circuit reliability. This paper proposes a fault detection and active thermal control strategy (ACT) based on junction temperature lifetime reliability feedback. It can detect whether the short circuit faults (SCFs) occurs in the secondary side silicon carbide (SiC) device by monitoring the junction temperature fluctuation of the primary side SiC device. The proposed ACT algorithm actively adjusts the circuit drive signal after the fault occurs to eliminate the fault in time. At the same time, it ensures effective fault monitoring without significantly sacrificing the lifetime of the primary side SiC devices.

Hasselt University (BE), KU Leuven (BE)
Affordable and clean energy
Openalex Percentile: Top 82%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DC Fault Diagnosis and Suppression Method of Dual Active Bridge Converters Based on Junction Temperature Reliability Feedback — Wilmar Martínez, Bangli Du, et al. · (2025) | TGRS Research Map | TGRS