Improved Control Strategy for Inverter Side Current Feedback of LCL Grid-Connected Inverter Under Weak Grid

In view of the inability to achieve unit power factor and the poor stability of the system under weak grids, this paper propose an improved control strategy for inverter side current feedback of LCL grid-connected inverter under weak grid which can using the capacitor voltage to achieve phase-locking, damping and grid-voltage feedback, calculate the reference current to achieve unity power factor correction by the calculation of the capacitance voltage and the inverter side current, and improve the stability of the system by complex filter. The theoretical analysis shows that the proposed improved control strategy has excellent performance under the weak grid and can achieve unit power factor integration. Finally, the correctness and effectiveness of the strategy are verified by simulation and experiment.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/ieecsc64206.2025.11100105
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Control Strategy for Inverter Side Current Feedback of LCL Grid-Connected Inverter Under Weak Grid

Shifeng Ou, Shuyin Duan, Kewen Li, Xiaoyong Yu et al.
Power Systems and Renewable Energy
article

Improved Control Strategy for Inverter Side Current Feedback of LCL Grid-Connected Inverter Under Weak Grid

Shifeng Ou, Shuyin Duan, Kewen Li, Xiaoyong Yu, Lvzerui Yuan, Xinhao Lin
article en

Abstract

In view of the inability to achieve unit power factor and the poor stability of the system under weak grids, this paper propose an improved control strategy for inverter side current feedback of LCL grid-connected inverter under weak grid which can using the capacitor voltage to achieve phase-locking, damping and grid-voltage feedback, calculate the reference current to achieve unity power factor correction by the calculation of the capacitance voltage and the inverter side current, and improve the stability of the system by complex filter. The theoretical analysis shows that the proposed improved control strategy has excellent performance under the weak grid and can achieve unit power factor integration. Finally, the correctness and effectiveness of the strategy are verified by simulation and experiment.

Electric Power Research Institute (US), China Southern Power Grid (China) (CN), Power Grid Corporation (India) (IN)
Affordable and clean energy
Openalex Percentile: Top 79%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improved Control Strategy for Inverter Side Current Feedback of LCL Grid-Connected Inverter Under Weak Grid — Shifeng Ou, Shuyin Duan, et al. · (2025) | TGRS Research Map | TGRS