Research on Low Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator

In the power system with high proportion of wind power generation equipment, when a fault occurs in the power grid due to the large capacity of wind turbines, direct removal may cause grid collapse, requiring wind turbines to continue to be remained interconnected with the power grid for a specified duration when the voltage drops, to provide a certain amount of reactive current to the grid. Upon the successful formulation of the equivalent model of the doubly fed induction generator (DFIG), the main control methods of DFIG are briefly discussed in this paper. The transient characteristics of DFIG during three-phase fault in power grid are studied in depth. The influence of voltage drop on the DC bus voltage of rotor-side converter and the current flowing through the rotor is analyzed. A control strategy is proposed to improve LVRT capability of DFIG by using DC unloading circuit and rotor dynamic virtual resistance. This study can not only improve the transient characteristics of DFIG, but also improve the stability of power grid operation with high proportion of new energy generators.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/ieecsc64206.2025.11099843
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Low Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator

Zhi Yuan, Xiaoqi Zhang, Jinli Lv, Jian‐Kang Zhang
Power Systems and Renewable Energy
article

Research on Low Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator

Zhi Yuan, Xiaoqi Zhang, Jinli Lv, Jian‐Kang Zhang
article en

Abstract

In the power system with high proportion of wind power generation equipment, when a fault occurs in the power grid due to the large capacity of wind turbines, direct removal may cause grid collapse, requiring wind turbines to continue to be remained interconnected with the power grid for a specified duration when the voltage drops, to provide a certain amount of reactive current to the grid. Upon the successful formulation of the equivalent model of the doubly fed induction generator (DFIG), the main control methods of DFIG are briefly discussed in this paper. The transient characteristics of DFIG during three-phase fault in power grid are studied in depth. The influence of voltage drop on the DC bus voltage of rotor-side converter and the current flowing through the rotor is analyzed. A control strategy is proposed to improve LVRT capability of DFIG by using DC unloading circuit and rotor dynamic virtual resistance. This study can not only improve the transient characteristics of DFIG, but also improve the stability of power grid operation with high proportion of new energy generators.

State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.