Preventive Control Model Considering Static Safety Constraints for Interconnected Power Grid

This paper proposes a preventive control model for interconnected power grids, which considers the static voltage stability, the thermal stability, and the transaction power limits. The preventive control model aims to minimize the control cost, with constraints including feasibility constraints under normal operating conditions, static voltage stability constraints, thermal stability constraints, and active power constraints of transmission interfaces between regional power grids under the contemplated fault conditions. This not only ensures the static voltage stability and thermal stability of interconnected power grids under various operating conditions, but also meets the transaction power limits between regional interfaces. In view of the hierarchical and partitioned management characteristics of interconnected power grids, a decomposition-coordination interior point method is adopted to solve the proposed optimization model. Simulation results demonstrate the correctness and effectiveness of the proposed preventive control model for interconnected power grids.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/ieecsc64206.2025.11099895
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preventive Control Model Considering Static Safety Constraints for Interconnected Power Grid

Xiuqiong Hu, Jingxuan Liu
Power Systems and Technologies
article

Preventive Control Model Considering Static Safety Constraints for Interconnected Power Grid

Xiuqiong Hu, Jingxuan Liu
article en

Abstract

This paper proposes a preventive control model for interconnected power grids, which considers the static voltage stability, the thermal stability, and the transaction power limits. The preventive control model aims to minimize the control cost, with constraints including feasibility constraints under normal operating conditions, static voltage stability constraints, thermal stability constraints, and active power constraints of transmission interfaces between regional power grids under the contemplated fault conditions. This not only ensures the static voltage stability and thermal stability of interconnected power grids under various operating conditions, but also meets the transaction power limits between regional interfaces. In view of the hierarchical and partitioned management characteristics of interconnected power grids, a decomposition-coordination interior point method is adopted to solve the proposed optimization model. Simulation results demonstrate the correctness and effectiveness of the proposed preventive control model for interconnected power grids.

Panzhihua University (CN)
Affordable and clean energy
Openalex Percentile: Top 82%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.