Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes

Accurate magnetic source reconstruction critically depends on high-sensitivity multi-axis measurements. Given the superior sensitivity provided by the spin-exchange relaxation-free (SERF) regime, the development of high-sensitivity multi-axis atomic magnetometers (AMs) based on SERF is of paramount importance. However, most existing multi-axis AMs rely on multiple high-frequency modulated magnetic fields, increasing the spin-exchange relaxation and leading to the complex crosstalk between nearby magnetometers in array applications, thus limiting the measurement performance. In this study, we propose a method for magnetic field measurement with tunable sensitive axes, based on all-optical dual-axis measurements. This method adjusts the direction of atomic spin precession by applying a bias magnetic field. It allows for flexible switching between the transverse dual-axis and longitudinal axis as needed, without introducing complex multi-axis modulated magnetic fields. Experimental results demonstrate transverse dual-axis sensitivities are 3 fT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> for the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</i>-axis and 2 fT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> for the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</i>-axis, while the longitudinal sensitivity for the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z</i>-axis is 6 fT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> after switching the sensitive axis. Our approach offers significant advantages over existing methods, particularly in eliminating crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Additionally, the successful detection of simulated magnetocardiography signals demonstrates the practical potential of this method.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3595633
Citations
2
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
2.49

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes

Bangcheng Han, Shushan Gao, Xiaoyu Li, Zhongyu Wang et al.
2 citations
IEEE Transactions on Instrumentation and Measurement
Atomic and Subatomic Physics Research
2.49
article

Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes

Bangcheng Han, Shushan Gao, Xiaoyu Li, Zhongyu Wang, Jianwei Sheng, Jixi Lu, Ziao Liu
article en
2 citations

Abstract

Accurate magnetic source reconstruction critically depends on high-sensitivity multi-axis measurements. Given the superior sensitivity provided by the spin-exchange relaxation-free (SERF) regime, the development of high-sensitivity multi-axis atomic magnetometers (AMs) based on SERF is of paramount importance. However, most existing multi-axis AMs rely on multiple high-frequency modulated magnetic fields, increasing the spin-exchange relaxation and leading to the complex crosstalk between nearby magnetometers in array applications, thus limiting the measurement performance. In this study, we propose a method for magnetic field measurement with tunable sensitive axes, based on all-optical dual-axis measurements. This method adjusts the direction of atomic spin precession by applying a bias magnetic field. It allows for flexible switching between the transverse dual-axis and longitudinal axis as needed, without introducing complex multi-axis modulated magnetic fields. Experimental results demonstrate transverse dual-axis sensitivities are 3 fT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> for the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</i>-axis and 2 fT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> for the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</i>-axis, while the longitudinal sensitivity for the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z</i>-axis is 6 fT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> after switching the sensitive axis. Our approach offers significant advantages over existing methods, particularly in eliminating crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Additionally, the successful detection of simulated magnetocardiography signals demonstrates the practical potential of this method.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Beihang University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 10%
Atomic and Subatomic Physics Research
2.49
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.