OPTNet: Optimized Pixel-Transformer Model for Adaptive Retinal Fundus Image Enhancement

Retinal low-quality images present significant challenges for accurate diagnosis and monitoring of eye diseases by obscuring critical anatomical features and reducing analytical precision. This study introduces OPTNet, an optimized pixel-wise transformer model designed to efficiently enhance degraded or low-quality retinal images. The proposed approach consists of three main stages: (1) pre-processing to standardize image dimensions and balance color channels, (2) model development, in which a lightweight ANN-based feature extractor learns retinal structures and generates self-measured quality labels, and (3) pixel-level transformation guided by these predicted labels to perform localized enhancement. The performance of OPTNet was evaluated using statistical metrics across various architectures during training and testing, and benchmarked on six public retinal datasets: DRIVE, CHASE-DB1, HRF, DRHAGIS, FIRE, and FIVES. A comprehensive evaluation was conducted using both full-reference and no-reference quality assessment (QA) metrics, supported by qualitative analysis. OPTNet achieved competitive results including a 21.3% improvement in NIQE and 17.8% reduction in BRISQUE compared with existing methods. The final scores included SSIM (0.1925), VIF (0.1911), BIF (1.3018), EME (11.1704), NIQE (4.0730), and BRISQUE (30.3003), indicating perceptual and structural enhancement. Additionally, it effectively preserved brightness and anatomical fidelity while minimizing distortion (CD = 0.4214), blur (0.0889), and artifacts (0.2903). In conclusion, OPTNet outperforms state-of-the-art enhancement techniques by striking a robust balance between quality improvement and artifact suppression, demonstrating its strong potential for integration into clinical ophthalmic diagnostic pipelines.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3596045
Citations
1
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OPTNet: Optimized Pixel-Transformer Model for Adaptive Retinal Fundus Image Enhancement

Mohd Yazed Ahmad, Somaya Adwan, Salmah Karman, Faisal Saeed Al-Qahtani
1 citations
IEEE Access
Retinal Imaging and Analysis
1.36
article

OPTNet: Optimized Pixel-Transformer Model for Adaptive Retinal Fundus Image Enhancement

Mohd Yazed Ahmad, Somaya Adwan, Salmah Karman, Faisal Saeed Al-Qahtani
article en
1 citations

Abstract

Retinal low-quality images present significant challenges for accurate diagnosis and monitoring of eye diseases by obscuring critical anatomical features and reducing analytical precision. This study introduces OPTNet, an optimized pixel-wise transformer model designed to efficiently enhance degraded or low-quality retinal images. The proposed approach consists of three main stages: (1) pre-processing to standardize image dimensions and balance color channels, (2) model development, in which a lightweight ANN-based feature extractor learns retinal structures and generates self-measured quality labels, and (3) pixel-level transformation guided by these predicted labels to perform localized enhancement. The performance of OPTNet was evaluated using statistical metrics across various architectures during training and testing, and benchmarked on six public retinal datasets: DRIVE, CHASE-DB1, HRF, DRHAGIS, FIRE, and FIVES. A comprehensive evaluation was conducted using both full-reference and no-reference quality assessment (QA) metrics, supported by qualitative analysis. OPTNet achieved competitive results including a 21.3% improvement in NIQE and 17.8% reduction in BRISQUE compared with existing methods. The final scores included SSIM (0.1925), VIF (0.1911), BIF (1.3018), EME (11.1704), NIQE (4.0730), and BRISQUE (30.3003), indicating perceptual and structural enhancement. Additionally, it effectively preserved brightness and anatomical fidelity while minimizing distortion (CD = 0.4214), blur (0.0889), and artifacts (0.2903). In conclusion, OPTNet outperforms state-of-the-art enhancement techniques by striking a robust balance between quality improvement and artifact suppression, demonstrating its strong potential for integration into clinical ophthalmic diagnostic pipelines.

IEEE AccessVol. 13
University of Malaya (MY)
Prince Sattam bin Abdulaziz University
Openalex Percentile: Top 17%
Retinal Imaging and Analysis
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.