3D-printed device for improved membrane-based extraction procedure of xenobiotics in complex matrices

• Innovative 3D printed Device for multi-FPSM array extraction. • Useful in complex matrix (both environmental and biological). • Direct sample stirring using built-in space for magnetic stirrer. • Higher recovery respect conventional FPSE procedures. To minimize the environmental and human health impacts of chemical processes, there is growing interest in eco-friendly methods aligned with the principles of Green Analytical Chemistry (GAC). A successful chemical analysis typically involves sample preparation, sampling, separation and analysis, quantification, and data interpretation. Among these, sample preparation plays a crucial role in isolating and preconcentrating target analytes from complex matrices. In 2014, fabric phase sorptive extraction (FPSE) was introduced as a simplified and greener sample pretreatment method. Building on this advancement and a recent patent, the present study introduces an innovative 3D-printed device designed for use with a range of target analytes and complex sample matrices. Constructed from inert materials, the device features a rigid, modular structure with multiple windows that securely hold various membrane-based extraction materials. These include FPSE membranes, electrospun membranes, and materials derived from adsorbent systems recovered from production or usage waste, as well as permeable molecularly imprinted polymers (MIPs). The device offers several advantages, including enhanced enrichment factors, compatibility with diverse planar membrane types, and highly customizable selectivity based on membrane configuration and chemistry. Its design also incorporates a built-in slot for a magnetic stirrer, enabling precise control of rotation speed during extraction-even in field conditions using a portable, battery-powered stirrer. Experimental results unequivocally demonstrate that the new device achieves superior enrichment factors compared to previously validated methods for the same analytes, confirming its effectiveness and potential for broader analytical applications.

Authors

Institutions

Publication Details

Journal
Advances in Sample Preparation
Published
2025-08-01
DOI
https://doi.org/10.1016/j.sampre.2025.100205
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-printed device for improved membrane-based extraction procedure of xenobiotics in complex matrices

Miryam Perrucci, Abuzar Kabir, Kenneth G. Furton, Marcello Locatelli et al.
Advances in Sample Preparation
Analytical chemistry methods development
article

3D-printed device for improved membrane-based extraction procedure of xenobiotics in complex matrices

Miryam Perrucci, Abuzar Kabir, Kenneth G. Furton, Marcello Locatelli, E. Ricci
article en

Abstract

• Innovative 3D printed Device for multi-FPSM array extraction. • Useful in complex matrix (both environmental and biological). • Direct sample stirring using built-in space for magnetic stirrer. • Higher recovery respect conventional FPSE procedures. To minimize the environmental and human health impacts of chemical processes, there is growing interest in eco-friendly methods aligned with the principles of Green Analytical Chemistry (GAC). A successful chemical analysis typically involves sample preparation, sampling, separation and analysis, quantification, and data interpretation. Among these, sample preparation plays a crucial role in isolating and preconcentrating target analytes from complex matrices. In 2014, fabric phase sorptive extraction (FPSE) was introduced as a simplified and greener sample pretreatment method. Building on this advancement and a recent patent, the present study introduces an innovative 3D-printed device designed for use with a range of target analytes and complex sample matrices. Constructed from inert materials, the device features a rigid, modular structure with multiple windows that securely hold various membrane-based extraction materials. These include FPSE membranes, electrospun membranes, and materials derived from adsorbent systems recovered from production or usage waste, as well as permeable molecularly imprinted polymers (MIPs). The device offers several advantages, including enhanced enrichment factors, compatibility with diverse planar membrane types, and highly customizable selectivity based on membrane configuration and chemistry. Its design also incorporates a built-in slot for a magnetic stirrer, enabling precise control of rotation speed during extraction-even in field conditions using a portable, battery-powered stirrer. Experimental results unequivocally demonstrate that the new device achieves superior enrichment factors compared to previously validated methods for the same analytes, confirming its effectiveness and potential for broader analytical applications.

Advances in Sample PreparationVol. 15
University of Teramo (IT), Florida International University (US), University of Chieti-Pescara (IT)
Openalex Percentile: Top 78%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.