Energy processes in load when operating from a combined power source with a supercapacitor and a battery

() - (). . , - ., ' , , - . - . Buck/Boost, - Boost () . - , . - ., C = 500 (), = 6,6 ( .). Matlab. ., 95 % . 3,3 6 (), . : ; ; ; ; ; ; ; .Energy processes in load when operating from a combined power source with a supercapacitor and a battery.Biletskyi O., Zaluskyi D.In this work, an analysis of energy processes in the load when powered by a combined power source with a supercapacitor battery (SC) and a lithium-ion battery was performed.An analysis of the energy characteristics of the discharge circuits of the combined power supply system was performed.The modes under which the SC battery provides pulsed power and the lithium-ion battery maintains long-term power consumption modes were investigated.It was proved that parallel connection of the SC battery to the battery reduces pulsed currents in it at all increases in active power in the load, provided that the internal resistance of the SC battery is less than the internal resistance of the lithium-ion battery.It was analyzed that when the internal resistance of the SC battery decreases with the unchanged resistance of the battery, the pulse current in the load and the ratio of currents in the SC battery and the battery increase.The equivalent circuit shows a hybrid source with SC and a lithium-ion battery.The SC battery is connected to a Buck/Boost converter, while the lithium-ion battery is connected to a Boost (boost) converter.The peak power of the lithium-ion battery is limited by electronics, and the power in the load at peak modes is covered by the SC battery.The energy characteristics of the SC battery and the lithium-ion AB were studied when they operate as part of a combined energy source for a common load.It was taken into account that the capacity of the SC battery was C SC = 500 (F), and the capacity of the AB, respectively, E AB = 6.6 (Ah).The simulation was carried out in the Matlab package.The results of the research were compared for different ranges of pulse power changes in the load.It was established that the pulse power in the load at the beginning of the transient process when working on the load is provided by 95% by the SC battery.The AB provides the required maximum power in the time range from 3.3 to 6 (s), at this time the SC battery does not work on the load and all the power is provided by the AB.

Authors

Publication Details

Journal
Ecological Sciences
Published
2025-01-01
DOI
https://doi.org/10.32846/2306-9716/2025.eco.3-60.19
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy processes in load when operating from a combined power source with a supercapacitor and a battery

O. Biletskyi, D. Zaluskyi
Ecological Sciences
Electric Power Systems and Control
article

Energy processes in load when operating from a combined power source with a supercapacitor and a battery

O. Biletskyi, D. Zaluskyi
article en

Abstract

() - (). . , - ., ' , , - . - . Buck/Boost, - Boost () . - , . - ., C = 500 (), = 6,6 ( .). Matlab. ., 95 % . 3,3 6 (), . : ; ; ; ; ; ; ; .Energy processes in load when operating from a combined power source with a supercapacitor and a battery.Biletskyi O., Zaluskyi D.In this work, an analysis of energy processes in the load when powered by a combined power source with a supercapacitor battery (SC) and a lithium-ion battery was performed.An analysis of the energy characteristics of the discharge circuits of the combined power supply system was performed.The modes under which the SC battery provides pulsed power and the lithium-ion battery maintains long-term power consumption modes were investigated.It was proved that parallel connection of the SC battery to the battery reduces pulsed currents in it at all increases in active power in the load, provided that the internal resistance of the SC battery is less than the internal resistance of the lithium-ion battery.It was analyzed that when the internal resistance of the SC battery decreases with the unchanged resistance of the battery, the pulse current in the load and the ratio of currents in the SC battery and the battery increase.The equivalent circuit shows a hybrid source with SC and a lithium-ion battery.The SC battery is connected to a Buck/Boost converter, while the lithium-ion battery is connected to a Boost (boost) converter.The peak power of the lithium-ion battery is limited by electronics, and the power in the load at peak modes is covered by the SC battery.The energy characteristics of the SC battery and the lithium-ion AB were studied when they operate as part of a combined energy source for a common load.It was taken into account that the capacity of the SC battery was C SC = 500 (F), and the capacity of the AB, respectively, E AB = 6.6 (Ah).The simulation was carried out in the Matlab package.The results of the research were compared for different ranges of pulse power changes in the load.It was established that the pulse power in the load at the beginning of the transient process when working on the load is provided by 95% by the SC battery.The AB provides the required maximum power in the time range from 3.3 to 6 (s), at this time the SC battery does not work on the load and all the power is provided by the AB.

Ecological Sciences(3 (60))
Affordable and clean energy
Openalex Percentile: Top 82%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.