Research on data center load simulation and optimization of integrated energy system

Adopting an integrated energy system (IES) to power data centers can enhance the system’s economic efficiency and promote low-carbon and high-efficiency operations. Existing research primarily focuses on analyzing the energy efficiency, economic viability, and environmental characteristics of data center integrated energy systems, as well as exploring the feasibility of various energy supply methods. However, there remains a scarcity of literature that incorporates optimized operational strategies into system optimization and conducts detailed comparative analyses. Based on this, this paper constructs a model of a medium-sized data center; its cooling, heating, and electrical loads are simulated throughout the year. The IES, consisting of a photovoltaic power generation system, gas turbine, waste heat boiler, electric chiller, and absorption chiller, is established. By comparing the operating strategies of Following Thermal Load (FTL) and Following Electric Load (FEL), an optimization analysis is then carried out to determine the integrated energy system configuration that minimizes the data center’s annual operating costs. The main contributions of this work include (1) load simulation of the entire data center building to analyze its heating, cooling, and electrical load characteristics; (2) comparison of the operational cost optimization of FTL and FEL strategies using particle swarm optimization algorithms; and (3) based on the optimization results, analysis of the output proportions of various equipment under different strategies, revealing that the FTL strategy reduces operating costs by 20%, 6%, and 7.2% in winter, summer, and the transition season, respectively, with winter days exhibiting the lowest costs, transitional seasons showing moderate costs, and summer days the highest. This strategy can effectively reduce the costs and instability of the IES and provide a reference for the design of energy supply systems for data centers.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0285371
Citations
2
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on data center load simulation and optimization of integrated energy system

S. Y. S. Y. Liang
2 citations
AIP Advances
Heat Transfer and Optimization
1.43
article

Research on data center load simulation and optimization of integrated energy system

S. Y. S. Y. Liang
article en
2 citations

Abstract

Adopting an integrated energy system (IES) to power data centers can enhance the system’s economic efficiency and promote low-carbon and high-efficiency operations. Existing research primarily focuses on analyzing the energy efficiency, economic viability, and environmental characteristics of data center integrated energy systems, as well as exploring the feasibility of various energy supply methods. However, there remains a scarcity of literature that incorporates optimized operational strategies into system optimization and conducts detailed comparative analyses. Based on this, this paper constructs a model of a medium-sized data center; its cooling, heating, and electrical loads are simulated throughout the year. The IES, consisting of a photovoltaic power generation system, gas turbine, waste heat boiler, electric chiller, and absorption chiller, is established. By comparing the operating strategies of Following Thermal Load (FTL) and Following Electric Load (FEL), an optimization analysis is then carried out to determine the integrated energy system configuration that minimizes the data center’s annual operating costs. The main contributions of this work include (1) load simulation of the entire data center building to analyze its heating, cooling, and electrical load characteristics; (2) comparison of the operational cost optimization of FTL and FEL strategies using particle swarm optimization algorithms; and (3) based on the optimization results, analysis of the output proportions of various equipment under different strategies, revealing that the FTL strategy reduces operating costs by 20%, 6%, and 7.2% in winter, summer, and the transition season, respectively, with winter days exhibiting the lowest costs, transitional seasons showing moderate costs, and summer days the highest. This strategy can effectively reduce the costs and instability of the IES and provide a reference for the design of energy supply systems for data centers.

AIP AdvancesVol. 15(8)
North China Electric Power University (CN)
Openalex Percentile: Top 18%
Heat Transfer and Optimization
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.