Charge measurement diagnostics with improved SNR and bit utilization for electron plasma confined in a partial toroidal trap

The SMall Aspect Ratio Toroidal EXperiment in a C-shaped torus recently reported an unprecedented electron plasma confinement, τconfine, of >100s. Understanding the plasma transport mechanism is essential to validate the observed long confinement. Measurement of the total charge Qtotal and its spatial and temporal evolution offers insight into the plasma transport mechanism. The existing charge collector for measuring Qtotal is affected by fast transients, resulting in a low signal-to-noise ratio (SNR) and insufficient bit resolution, which makes its measurement difficult, especially at long confinement times. This restricted the measurement of Qtotal only to about 20 ms. The upgraded charge collector has modified switching circuitry and has utilized components that are carefully considered to mitigate the effect of transients. The resulting increase in SNR and improvement in bit resolution have thereby allowed measurement of Qtotal for extended confinement periods of up to 30 s.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0281096
Primary Topic
Atomic and Molecular Physics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Charge measurement diagnostics with improved SNR and bit utilization for electron plasma confined in a partial toroidal trap

Minsha Shah, Prabal Kumar Chattopadhyay, S. Pahari, Lavkesh Lachhvani et al.
AIP Advances
Atomic and Molecular Physics
article

Charge measurement diagnostics with improved SNR and bit utilization for electron plasma confined in a partial toroidal trap

Minsha Shah, Prabal Kumar Chattopadhyay, S. Pahari, Lavkesh Lachhvani, Nikhil Mohurle
article en

Abstract

The SMall Aspect Ratio Toroidal EXperiment in a C-shaped torus recently reported an unprecedented electron plasma confinement, τconfine, of >100s. Understanding the plasma transport mechanism is essential to validate the observed long confinement. Measurement of the total charge Qtotal and its spatial and temporal evolution offers insight into the plasma transport mechanism. The existing charge collector for measuring Qtotal is affected by fast transients, resulting in a low signal-to-noise ratio (SNR) and insufficient bit resolution, which makes its measurement difficult, especially at long confinement times. This restricted the measurement of Qtotal only to about 20 ms. The upgraded charge collector has modified switching circuitry and has utilized components that are carefully considered to mitigate the effect of transients. The resulting increase in SNR and improvement in bit resolution have thereby allowed measurement of Qtotal for extended confinement periods of up to 30 s.

AIP AdvancesVol. 15(8)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN), Institute for Plasma Research (IN)
Openalex Percentile: Top 85%
Atomic and Molecular Physics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.