Photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer

Photoacoustic-computed tomography is a novel imaging technique that combines high absorption contrast and deep tissue penetration capability, enabling comprehensive three-dimensional imaging of biological targets. However, the increasing demand for higher resolution and real-time imaging results in significant data volume, limiting data storage, transmission and processing efficiency of system. Therefore, there is an urgent need for an effective method to compress the raw data without compromising image quality. This paper presents a photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer. This method is based on the cooperative compression framework that integrates wavelet hard coding with deep learning-based soft decoding. It combines the multi-scale analysis capability of wavelet transforms with the global feature modeling advantage of Transformers, achieving high-quality data compression and reconstruction. Experimental results using k-wave simulation suggest that the proposed compression system has advantages under extreme compression conditions, achieving a raw data compression ratio of up to 1:40. Furthermore, three-dimensional data compression experiment using in vivo mouse demonstrated that the maximum peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) values of reconstructed images reached 38.60 and 0.9583, effectively overcoming detail loss and artifacts introduced by raw data compression. All the results suggest that the proposed system can significantly reduce storage requirements and hardware cost, enhancing computational efficiency and image quality. These advantages support the development of photoacoustic-computed tomography toward higher efficiency, real-time performance and intelligent functionality.

Authors

Institutions

Publication Details

Journal
Journal of Innovative Optical Health Sciences
Published
2025-07-18
DOI
https://doi.org/10.1142/s1793545825500294
Citations
1
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer

Jialin Li, Tingting Li, Mingjian Sun, Yiming Ma et al.
1 citations
Journal of Innovative Optical Health Sciences
Photoacoustic and Ultrasonic Imaging
0.67
article

Photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer

Jialin Li, Tingting Li, Mingjian Sun, Yiming Ma, Yi Shen
article en
1 citations

Abstract

Photoacoustic-computed tomography is a novel imaging technique that combines high absorption contrast and deep tissue penetration capability, enabling comprehensive three-dimensional imaging of biological targets. However, the increasing demand for higher resolution and real-time imaging results in significant data volume, limiting data storage, transmission and processing efficiency of system. Therefore, there is an urgent need for an effective method to compress the raw data without compromising image quality. This paper presents a photoacoustic-computed tomography 3D data compression method and system based on Wavelet-Transformer. This method is based on the cooperative compression framework that integrates wavelet hard coding with deep learning-based soft decoding. It combines the multi-scale analysis capability of wavelet transforms with the global feature modeling advantage of Transformers, achieving high-quality data compression and reconstruction. Experimental results using k-wave simulation suggest that the proposed compression system has advantages under extreme compression conditions, achieving a raw data compression ratio of up to 1:40. Furthermore, three-dimensional data compression experiment using in vivo mouse demonstrated that the maximum peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) values of reconstructed images reached 38.60 and 0.9583, effectively overcoming detail loss and artifacts introduced by raw data compression. All the results suggest that the proposed system can significantly reduce storage requirements and hardware cost, enhancing computational efficiency and image quality. These advantages support the development of photoacoustic-computed tomography toward higher efficiency, real-time performance and intelligent functionality.

Journal of Innovative Optical Health SciencesVol. 19(01)
Harbin Institute of Technology (CN), Suzhou Research Institute (CN), Heilongjiang Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 28%
Photoacoustic and Ultrasonic Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.