Power Doppler and color flow imaging with null subtraction imaging

Null subtraction imaging (NSI) is a nonlinear beamforming technique that uses nulls in a beam pattern instead of the mainlobe to beat the diffraction limit. In this study, we used a 256-element linear array with 55-μm pitch to image the microvasculature of a mouse brain using NSI and delay and sum (DAS) with plane wave compounding. We also explored combining pulse inversion (PI) with NSI, i.e., we transmitted pulses at center frequency of 15.6 MHz to obtain the second harmonic at 31.2 MHz. Color flow imaging (CFI) at the fundamental frequency was also generated using traditional methods and NSI and compared. Higher spatial resolution and contrast in power Doppler images were observed in the NSI images compared to DAS (spatial resolution of 1/4–1/6 of a wavelength). The CFI images constructed using NSI resolved small vessels with flows in opposite directions that were not observed in the CFI using DAS, where vessels of opposite flows appeared averaged together as one vessel due to lower spatial resolution. The computation time was increased by only 40% for NSI compared to DAS. No contrast agents were used in these images.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-04-01
DOI
https://doi.org/10.1121/10.0037368
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power Doppler and color flow imaging with null subtraction imaging

Michael L. Oelze, Zhengchang Kou
The Journal of the Acoustical Society of America
Ultrasound Imaging and Elastography
article

Power Doppler and color flow imaging with null subtraction imaging

Michael L. Oelze, Zhengchang Kou
article en

Abstract

Null subtraction imaging (NSI) is a nonlinear beamforming technique that uses nulls in a beam pattern instead of the mainlobe to beat the diffraction limit. In this study, we used a 256-element linear array with 55-μm pitch to image the microvasculature of a mouse brain using NSI and delay and sum (DAS) with plane wave compounding. We also explored combining pulse inversion (PI) with NSI, i.e., we transmitted pulses at center frequency of 15.6 MHz to obtain the second harmonic at 31.2 MHz. Color flow imaging (CFI) at the fundamental frequency was also generated using traditional methods and NSI and compared. Higher spatial resolution and contrast in power Doppler images were observed in the NSI images compared to DAS (spatial resolution of 1/4–1/6 of a wavelength). The CFI images constructed using NSI resolved small vessels with flows in opposite directions that were not observed in the CFI using DAS, where vessels of opposite flows appeared averaged together as one vessel due to lower spatial resolution. The computation time was increased by only 40% for NSI compared to DAS. No contrast agents were used in these images.

The Journal of the Acoustical Society of AmericaVol. 157(4_Supplement)
University of Illinois Urbana-Champaign (US)
Openalex Percentile: Top 72%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.