Influence of Torque Type and Bone Loss on the Stability Quotient of Two Implants with Prostheses

Osseointegration is related to the stability of the screw and influences the success rate of implant-supported prosthetic rehabilitation, as it promotes natural healing and effective bone formation, facilitating the preservation of the implant in the recipient site. Factors such as surgical technique, insertion torque, the type of recipient bone, and the macro- and microstructure of the implant can affect screw stability. The objective of this study is to analyze in vivo the influence of insertion torque, recipient bone type, and peri-implant bone loss on the implant stability quotient (ISQ) values of cylindrical implants with external hexagon (EH) and Morse taper (MT) connections, featuring a new surface treatment called referenced acid etching (RAE). A total of 40 implants were placed in edentulous areas following predefined inclusion and exclusion criteria. Immediately after implant placement (t0), insertion torque, resonance frequency, digital periapical radiographs, and peri-implant evaluation were recorded. Resonance frequency analysis, periapical radiographs, and peri-implant evaluations were repeated after osseointegration (t1) and 180 d after rehabilitation (t2). The data obtained were statistically analyzed using specific tests for each type of analysis, with a significance level of 5%. Regarding the ISQ value at t1, it resulted in a high value, with a significant reduction at t2, for both types of connection, there was bone resorption for the HE and bone gain for the MT. The installation of the implants up to 180 d of prosthesis functionality, stability, bone gain or loss and type of bone, presented clinically acceptable conditions for all connections studied.

Authors

Institutions

Publication Details

Journal
Journal of Long-Term Effects of Medical Implants
Published
2025-01-01
DOI
https://doi.org/10.1615/jlongtermeffmedimplants.2025060463
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Torque Type and Bone Loss on the Stability Quotient of Two Implants with Prostheses

Lisiane Cristina Bannwart, Emily Vivianne Freitas da Silva, Lucas do Nascimento Tavares, Marcelo Coelho Goiato et al.
Journal of Long-Term Effects of Medical Implants
Dental Implant Techniques and Outcomes
article

Influence of Torque Type and Bone Loss on the Stability Quotient of Two Implants with Prostheses

Lisiane Cristina Bannwart, Emily Vivianne Freitas da Silva, Lucas do Nascimento Tavares, Marcelo Coelho Goiato, Daniela dos Santos, Clóvis Lamartinede Moraes Melo Neto, João Souza
article en

Abstract

Osseointegration is related to the stability of the screw and influences the success rate of implant-supported prosthetic rehabilitation, as it promotes natural healing and effective bone formation, facilitating the preservation of the implant in the recipient site. Factors such as surgical technique, insertion torque, the type of recipient bone, and the macro- and microstructure of the implant can affect screw stability. The objective of this study is to analyze in vivo the influence of insertion torque, recipient bone type, and peri-implant bone loss on the implant stability quotient (ISQ) values of cylindrical implants with external hexagon (EH) and Morse taper (MT) connections, featuring a new surface treatment called referenced acid etching (RAE). A total of 40 implants were placed in edentulous areas following predefined inclusion and exclusion criteria. Immediately after implant placement (t0), insertion torque, resonance frequency, digital periapical radiographs, and peri-implant evaluation were recorded. Resonance frequency analysis, periapical radiographs, and peri-implant evaluations were repeated after osseointegration (t1) and 180 d after rehabilitation (t2). The data obtained were statistically analyzed using specific tests for each type of analysis, with a significance level of 5%. Regarding the ISQ value at t1, it resulted in a high value, with a significant reduction at t2, for both types of connection, there was bone resorption for the HE and bone gain for the MT. The installation of the implants up to 180 d of prosthesis functionality, stability, bone gain or loss and type of bone, presented clinically acceptable conditions for all connections studied.

Journal of Long-Term Effects of Medical ImplantsVol. 35(4)
Universidade de São Paulo (BR), Universidade São Francisco (BR), Universidade Estadual Paulista (Unesp) (BR)
Openalex Percentile: Top 72%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.