Phase characteristic of a Mach–Zehnder interferometric acoustic sensor

A push–pull Mach–Zehnder interferometric acoustic sensor is composed of two parallel fiber optic line sensor elements separated by one-half acoustic wavelength. The maximum signal response or optical path difference occurs for a plane acoustic wave with an acoustic wave angle of ±90° since one line sensor will be in a sound pressure peak while the other is in a sound pressure trough. The minimum signal occurs with an acoustic wave angle of 0° or 180° since both line sensors experience the same sound pressure variations. A phase characteristic of the sensor is obtained by evaluating the optical path difference equation at acoustic wave angles from 0° to 360°. At each acoustic wave angle, the phase of the peak optical path difference is plotted against the acoustic wave angle. The phase characteristic indicates from which side of the line sensors the acoustic wave arrives. Using the magnitude response alone it is not possible to determine which side of the line sensors from where the acoustic wave arrives.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-04-01
DOI
https://doi.org/10.1121/10.0037710
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Phase characteristic of a Mach–Zehnder interferometric acoustic sensor

Michael S. McBeth
The Journal of the Acoustical Society of America
Advanced Fiber Optic Sensors
article

Phase characteristic of a Mach–Zehnder interferometric acoustic sensor

Michael S. McBeth
article en

Abstract

A push–pull Mach–Zehnder interferometric acoustic sensor is composed of two parallel fiber optic line sensor elements separated by one-half acoustic wavelength. The maximum signal response or optical path difference occurs for a plane acoustic wave with an acoustic wave angle of ±90° since one line sensor will be in a sound pressure peak while the other is in a sound pressure trough. The minimum signal occurs with an acoustic wave angle of 0° or 180° since both line sensors experience the same sound pressure variations. A phase characteristic of the sensor is obtained by evaluating the optical path difference equation at acoustic wave angles from 0° to 360°. At each acoustic wave angle, the phase of the peak optical path difference is plotted against the acoustic wave angle. The phase characteristic indicates from which side of the line sensors the acoustic wave arrives. Using the magnitude response alone it is not possible to determine which side of the line sensors from where the acoustic wave arrives.

The Journal of the Acoustical Society of AmericaVol. 157(4_Supplement)
Naval Surface Warfare Center (US)
Openalex Percentile: Top 82%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.