Cochlear implant perception of prosody is especially vulnerable to noise

Perceiving prosody is essential for understanding a talker’s intended meaning. For listeners with typical hearing (TH), the perception of voice pitch can withstand a high amount of background noise. However, listeners with cochlear implants (CI) lack access to harmonic pitch perception, putting them at risk for poor perception of prosody when noise is present, even if they appear to perceive pitch adequately in quiet. The current study tested the hypothesis that prosodic focus would be more heavily affected by noise for CI users compared to listeners with typical hearing. Stimuli were sentences with a contrastive focus on a specific word as if to correct prior information. The sentences were embedded in various levels of speech-shaped noise and presented with accompanying text to test only prosody rather than word identification ability. Participants used a visual analog scale to report the perceived degree of focus on words in each sentence. Results from TH listeners were essentially unaffected by noise regardless of the noise level (even down to −5 dB SNR). Conversely, CI users showed a high probability of misinterpreting which word was emphasized in sentences with any background noise, even with a favorable SNR of +10 dB, compared to their performance in quiet.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-04-01
DOI
https://doi.org/10.1121/10.0038043
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cochlear implant perception of prosody is especially vulnerable to noise

Matthew B. Winn, Harley J. Wheeler
The Journal of the Acoustical Society of America
Hearing Loss and Rehabilitation
article

Cochlear implant perception of prosody is especially vulnerable to noise

Matthew B. Winn, Harley J. Wheeler
article en

Abstract

Perceiving prosody is essential for understanding a talker’s intended meaning. For listeners with typical hearing (TH), the perception of voice pitch can withstand a high amount of background noise. However, listeners with cochlear implants (CI) lack access to harmonic pitch perception, putting them at risk for poor perception of prosody when noise is present, even if they appear to perceive pitch adequately in quiet. The current study tested the hypothesis that prosodic focus would be more heavily affected by noise for CI users compared to listeners with typical hearing. Stimuli were sentences with a contrastive focus on a specific word as if to correct prior information. The sentences were embedded in various levels of speech-shaped noise and presented with accompanying text to test only prosody rather than word identification ability. Participants used a visual analog scale to report the perceived degree of focus on words in each sentence. Results from TH listeners were essentially unaffected by noise regardless of the noise level (even down to −5 dB SNR). Conversely, CI users showed a high probability of misinterpreting which word was emphasized in sentences with any background noise, even with a favorable SNR of +10 dB, compared to their performance in quiet.

The Journal of the Acoustical Society of AmericaVol. 157(4_Supplement)
University of Minnesota (US)
No poverty
Openalex Percentile: Top 81%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.