Laser-based primary calibration for microbarometers

In previous work, the National Center for Physical Acoustics at the University of Mississippi designed and built a large chamber for secondary (referenced) calibration of microbarometers. Sandia National Laboratories (SNL) then refined and implemented this chamber at their Facility for Acceptance, Calibration, and Testing (FACT) site. These large chambers incorporate moving coil loudspeakers capable of operating in receive and transmit modes, and in more recent work, Penn State University (PSU) and SNL used these loudspeakers to implement a reciprocity-based primary (non-referenced) calibration technique. Unfortunately, while this technique has been shown to have suitable uncertainty above 0.05 Hz, uncertainty increases rapidly below this frequency. Due to this, the authors are investigating a new chamber-based calibration technique that may provide better results within the 0.01–0.05 Hz band. This method uses a laser-based sensor to monitor loudspeaker displacement, in combination with a model of the acoustic chamber, to estimate the acoustic pressure at a sensor under test. The use of these two calibration methods may enable primary calibration over the full band of interest (0.01–10.0 Hz) and lend credence to each method. This talk will discuss low-band calibration challenges, the laser-based method, and calibration results.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-04-01
DOI
https://doi.org/10.1121/10.0038031
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Laser-based primary calibration for microbarometers

B. J. Merchant, Chad M. Smith, Thomas B. Gabrielson
1 links
The Journal of the Acoustical Society of America
Sensor Technology and Measurement Systems
article

Laser-based primary calibration for microbarometers

B. J. Merchant, Chad M. Smith, Thomas B. Gabrielson
article en

Abstract

In previous work, the National Center for Physical Acoustics at the University of Mississippi designed and built a large chamber for secondary (referenced) calibration of microbarometers. Sandia National Laboratories (SNL) then refined and implemented this chamber at their Facility for Acceptance, Calibration, and Testing (FACT) site. These large chambers incorporate moving coil loudspeakers capable of operating in receive and transmit modes, and in more recent work, Penn State University (PSU) and SNL used these loudspeakers to implement a reciprocity-based primary (non-referenced) calibration technique. Unfortunately, while this technique has been shown to have suitable uncertainty above 0.05 Hz, uncertainty increases rapidly below this frequency. Due to this, the authors are investigating a new chamber-based calibration technique that may provide better results within the 0.01–0.05 Hz band. This method uses a laser-based sensor to monitor loudspeaker displacement, in combination with a model of the acoustic chamber, to estimate the acoustic pressure at a sensor under test. The use of these two calibration methods may enable primary calibration over the full band of interest (0.01–10.0 Hz) and lend credence to each method. This talk will discuss low-band calibration challenges, the laser-based method, and calibration results.

The Journal of the Acoustical Society of AmericaVol. 157(4_Supplement)
Pennsylvania State University (US), Sandia National Laboratories (US)
Openalex Percentile: Top 78%
Sensor Technology and Measurement Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laser-based primary calibration for microbarometers — B. J. Merchant, Chad M. Smith, et al. · The Journal of the Acoustical Society of America (2025) | TGRS Research Map | TGRS