An Active Silicon Perforated Mea for Seamless 3D Organoid Interfacing with Low-Noise, Scalable Multimodal Electrophysiology

We present the first active silicon perforated MEA for 3D organoid interfacing, integrating CMOS electronics for lownoise, high-resolution recording, stimulation, and impedance spectroscopy (EIS) across 7 modalities. The MEA, fabricated in 130 nm CMOS technology, features a scalable 256 -island mesh with multiplexed operation, achieving low input-referred noise (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$9.1 \pm 1.5 \mu \mathrm{V}_{\text {rms }}, 300 \text{Hz}-10 \text{kHz}$</tex>) and low power (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$11.3 \mu \mathrm{W}$</tex> per island). In vitro tests with cardiomyocytes demonstrate accurate recordings, network propagation mapping, and intracellular recordings via voltage stimulation. This perforated MEA offers unparalleled functionality and scalability for advancing organ-on-chip research.

Authors

Institutions

Publication Details

Published
2025-06-08
DOI
https://doi.org/10.23919/vlsitechnologyandcir65189.2025.11075224
Primary Topic
Neuroscience and Neural Engineering
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Active Silicon Perforated Mea for Seamless 3D Organoid Interfacing with Low-Noise, Scalable Multimodal Electrophysiology

Carolina Mora López, Georges Gielen, Joan Aymerich, Andrea Lodi et al.
1 links
Neuroscience and Neural Engineering
article

An Active Silicon Perforated Mea for Seamless 3D Organoid Interfacing with Low-Noise, Scalable Multimodal Electrophysiology

Carolina Mora López, Georges Gielen, Joan Aymerich, Andrea Lodi, Sohail F. Shaikh, Bogdan Raducanu, Aitor Rivero-Cortazar
article en

Abstract

We present the first active silicon perforated MEA for 3D organoid interfacing, integrating CMOS electronics for lownoise, high-resolution recording, stimulation, and impedance spectroscopy (EIS) across 7 modalities. The MEA, fabricated in 130 nm CMOS technology, features a scalable 256 -island mesh with multiplexed operation, achieving low input-referred noise (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$9.1 \pm 1.5 \mu \mathrm{V}_{\text {rms }}, 300 \text{Hz}-10 \text{kHz}$</tex>) and low power (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$11.3 \mu \mathrm{W}$</tex> per island). In vitro tests with cardiomyocytes demonstrate accurate recordings, network propagation mapping, and intracellular recordings via voltage stimulation. This perforated MEA offers unparalleled functionality and scalability for advancing organ-on-chip research.

IMEC (BE)
Fonds Wetenschappelijk Onderzoek
Openalex Percentile: Top 79%
Neuroscience and Neural Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Active Silicon Perforated Mea for Seamless 3D Organoid Interfacing with Low-Noise, Scalable Multimodal Electrophysiology — Carolina Mora López, Georges Gielen, et al. · (2025) | TGRS Research Map | TGRS